With the increasement of pulverized coal utility boiler capacity, whether increasing the single burner heat power or not has not been confirmed. The mathematic model of realizable k-ε and discrete particle model (DPM) are used to describe the gas and solid phase flowing. The P-1 radiation model and the probability density function (PDF) model are utilized to solve radiation heat transfer and heat chemical calculation. The calculation results display the detailed aerodynamics field and temperature distribution in 600MW utility boiler which satisfies with actual operation conditions. The burners and OFA effectively organize the aerodynamic field in boiler. Pulverized coal starts burning after a short time away from spouts. Through discussing ignition distance, fuel conversion, NOx emission, outlet velocity and temperature, and hot corrosion tendency, it is found that burner single power obviously affected ignition distance and hot corrosion. The condition of furnace with 48 burners installed in 600MW boiler is considered having a better performance.
Skip Nav Destination
ASME 2011 Power Conference collocated with JSME ICOPE 2011
July 12–14, 2011
Denver, Colorado, USA
Conference Sponsors:
- Power Division
ISBN:
978-0-7918-4459-5
PROCEEDINGS PAPER
Numerical Simulation Research on 600MW Boiler With Different Single Burner Heat Power
Rui Luo,
Rui Luo
Xi’an Jiaotong University, Xi’an, Shaanxi, China
Search for other works by this author on:
Na Li,
Na Li
Xi’an Jiaotong University, Xi’an, Shaanxi, China
Search for other works by this author on:
Qulan Zhou,
Qulan Zhou
Xi’an Jiaotong University, Xi’an, Shaanxi, China
Search for other works by this author on:
Shi’en Hui,
Shi’en Hui
Xi’an Jiaotong University, Xi’an, Shaanxi, China
Search for other works by this author on:
Qinxin Zhao
Qinxin Zhao
Xi’an Jiaotong University, Xi’an, Shaanxi, China
Search for other works by this author on:
Rui Luo
Xi’an Jiaotong University, Xi’an, Shaanxi, China
Na Li
Xi’an Jiaotong University, Xi’an, Shaanxi, China
Qulan Zhou
Xi’an Jiaotong University, Xi’an, Shaanxi, China
Shi’en Hui
Xi’an Jiaotong University, Xi’an, Shaanxi, China
Qinxin Zhao
Xi’an Jiaotong University, Xi’an, Shaanxi, China
Paper No:
POWER2011-55351, pp. 99-105; 7 pages
Published Online:
February 28, 2012
Citation
Luo, R, Li, N, Zhou, Q, Hui, S, & Zhao, Q. "Numerical Simulation Research on 600MW Boiler With Different Single Burner Heat Power." Proceedings of the ASME 2011 Power Conference collocated with JSME ICOPE 2011. ASME 2011 Power Conference, Volume 1. Denver, Colorado, USA. July 12–14, 2011. pp. 99-105. ASME. https://doi.org/10.1115/POWER2011-55351
Download citation file:
5
Views
Related Proceedings Papers
Related Articles
A Method for Reduction in the Start-Up Time of a Bubbling Bed Boiler Combustor
J. Energy Resour. Technol (September,2010)
Options for Biomass Utilization in Coal Fired Power Stations
J. Thermal Sci. Eng. Appl (December,2009)
Thermodynamic Analysis and Comparison on Oxy-Fuel Power Generation Process
J. Eng. Gas Turbines Power (September,2009)
Related Chapters
Front Matter
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 1 Sixth Edition
Front Matter
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 2, Sixth Edition
Lay-Up and Start-Up Practices
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration