Flow meter performance is described by the dimensionless numbers of discharge coefficient and Reynolds number. To achieve the best flow measurement uncertainty, meters are tested (calibrated) to determine the discharge coefficient behavior versus Reynolds number (magnitude and slope). Various meter designs have differing Reynolds number dependence. In many cases calibration laboratories can not achieve the Reynolds number at which the flow meter will operate. This deficiency is usually due to fluid properties (density and viscosity) at operating conditions being considerably different than those in a water-based calibration laboratory. Testing using fluids such as natural gas may increase the achievable Reynolds number but it is difficult to achieve the low uncertainty of the discharge coefficient possible in a water calibration due to the additional uncertainty of the expansion factor required with compressible fluids and the problems associated with gravimetric measurements of compressible fluids. In some power industry applications, operating Reynolds numbers may be an order of magnitude higher than can be achieved during calibration. Therefore, calibration data must be used to infer the discharge coefficient at operating conditions (Reynolds number), defining extrapolation. In Code tests, minimum flow measurement uncertainty is the objective and the uncertainty must be estimated. The largest uncertainty component in a flow measurement application usually is the discharge coefficient, which is dependent on the care of fabrication, the calibration data, and the extrapolation process. Measured discharge coefficients of Throat Tap Nozzles, Venturi meters Wall Tap Nozzles, and Orifice Meters are compared to predictive equations.
Skip Nav Destination
ASME 2008 Power Conference
July 22–24, 2008
Lake Buena Vista, Florida, USA
Conference Sponsors:
- Power Division
ISBN:
0-7918-4832-9
PROCEEDINGS PAPER
Performance of Nozzle, Venturi, and Orifice Meters Relative to Extrapolation Criteria
James B. Nystrom,
James B. Nystrom
Alden Research Laboratory, Inc., Holden, MA
Search for other works by this author on:
Phillip S. Stacy
Phillip S. Stacy
Alden Research Laboratory, Inc., Holden, MA
Search for other works by this author on:
James B. Nystrom
Alden Research Laboratory, Inc., Holden, MA
Phillip S. Stacy
Alden Research Laboratory, Inc., Holden, MA
Paper No:
POWER2008-60112, pp. 509-513; 5 pages
Published Online:
July 8, 2009
Citation
Nystrom, JB, & Stacy, PS. "Performance of Nozzle, Venturi, and Orifice Meters Relative to Extrapolation Criteria." Proceedings of the ASME 2008 Power Conference. ASME 2008 Power Conference. Lake Buena Vista, Florida, USA. July 22–24, 2008. pp. 509-513. ASME. https://doi.org/10.1115/POWER2008-60112
Download citation file:
26
Views
Related Proceedings Papers
Related Articles
Extrapolation and Curve-Fitting of Calibration Data for Differential Pressure Flow Meters
J. Eng. Gas Turbines Power (February,2010)
Field Calibration of Orifice Meters for Natural Gas Flow
J. Energy Resour. Technol (March,1989)
Related Chapters
Antilock-Braking System Using Fuzzy Logic
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
A Simple Carburetor
Case Studies in Fluid Mechanics with Sensitivities to Governing Variables
Studies Performed
Closed-Cycle Gas Turbines: Operating Experience and Future Potential