A Borelex, Inc. Power Plant in Ashland, Maine had a need to evaluate their Surface Condenser. The unit had 27 tubes that were previously plugged. The unit had steam impingement troubles in the past and the plant wanted to focus the inspection in this area. The condenser contains 6,084 tubes that are 7/8″ OD, 0.049″ wall, 303″ long, admiralty brass. The plant decided to use the Eddy Current Technique (ECT) to inspect 600 tubes. The condenser uses local river water. TesTex told the plant the unit could be inspected and a color-coded tube sheet map showing the results could be completed in one shift. The contractor arrived at the plant at 7 am. The crew went through the usual plant indoctrination and safety training. Testing on the condenser using an Air-Assist System, the contractor was able to inspect the 600 tubes, perform analysis, and present a color-coded tube sheet map by 5 pm. A total of nine tubes showed wall thinning greater than 60%, which were recommended for plugging. The preliminary report provided listed the flaw locations and whether the defects were located on the I.D. or O.D. of the tube. In addition to this inspection, the plant also performed a hydro-pressure test to find any additional tube leaks. A few more tube leaks were found in areas that were not inspected with eddy current. These leaks along with the 9 tubes recommended for plugging were plugged. Prior to this inspection the plant felt the issues with the condenser were leaks in the joint between the tube and the tubesheet, where the tube has been rolled. The inspection showed the most severe wall losses found were on the O.D. of the tubes at various locations along the length of the tube. The tubes with wall losses less than 60% showed I.D. thinning at various places along the length of the tube. The effects of the tube plugging were that the water chemistry is better than ever and the vacuum pressure is higher than before.
Skip Nav Destination
Sign In or Register for Account
ASME 2008 Power Conference
July 22–24, 2008
Lake Buena Vista, Florida, USA
Conference Sponsors:
- Power Division
ISBN:
0-7918-4832-9
PROCEEDINGS PAPER
The Use of an Eddy Current Inspection of Brass Tubes in a Surface Condenser to Provide a Condition Assessment
Shawn Gowatski
,
Shawn Gowatski
TesTex, Inc., Pittsburgh, PA
Search for other works by this author on:
Tim Mitchell
Tim Mitchell
Boralex Ashland, Ashland, ME
Search for other works by this author on:
Shawn Gowatski
TesTex, Inc., Pittsburgh, PA
Tim Mitchell
Boralex Ashland, Ashland, ME
Paper No:
POWER2008-60061, pp. 405-409; 5 pages
Published Online:
July 8, 2009
Citation
Gowatski, S, & Mitchell, T. "The Use of an Eddy Current Inspection of Brass Tubes in a Surface Condenser to Provide a Condition Assessment." Proceedings of the ASME 2008 Power Conference. ASME 2008 Power Conference. Lake Buena Vista, Florida, USA. July 22–24, 2008. pp. 405-409. ASME. https://doi.org/10.1115/POWER2008-60061
Download citation file:
Sign In
8
Views
0
Citations
Related Proceedings Papers
Related Articles
Detection and Sizing of Defects in Control Rod Drive Mechanism Penetrations Using Eddy Current and Ultrasonics
J. Pressure Vessel Technol (August,1996)
Eddy Current Examination of Fatigue Cracks in Inconel Welds
J. Pressure Vessel Technol (February,2007)
Small Diameter Remote Field Eddy Current Inspection for Unpiggable Pipelines
J. Pressure Vessel Technol (August,2005)
Related Chapters
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Scope
Consensus on Operating Practices for the Sampling and Monitoring of Feedwater and Boiler Water Chemistry in Modern Industrial Boilers (CRTD-81)
Engineering and Physical Modeling of Power Plant Cooling Systems
Thermal Power Plant Cooling: Context and Engineering