The Heat Exchange Institute (HEI) Standards for Steam Surface Condensers are used to design and predict the performance of condensers for power plant applications. Since their inception, the Standards have undergone numerous changes to incorporate technological advances and revisions to various factors based on testing and operating experiences. Admiralty and copper-nickel (CuNi) tubes were very popular until the 1970’s. Subsequently, increasing concerns with the use of copper-based alloys in nuclear power plants as well as other factors led to specification and use of stainless steel (SS) and titanium. The first condenser designed with titanium tubes was put into service in 1977. In 1978, the HEI published the seventh edition of the HEI Standards for Steam Surface Condensers. The eighth edition was issued in 1984 followed by Addendum 1 in 1989. The ninth edition was issued in 1995 and Addendum 1 to the ninth edition was published in 2002. Notable differences between the ninth and seventh editions include: higher circulating water inlet temperature correction factors below 70.0 °F; for Admiralty, higher tube material and gauge correction factors for tube wall gauge below 16 BWG and lower values above 20 BWG; for 90/10 CuNi and 304 SS, higher tube material and gauge correction factors for tube wall gauge between 12 BWG and 24 BWG; and, for titanium, higher tube material and gauge correction factors for tube wall gauge above 18 BWG. Depending upon the tube diameter, material, wall gauge and the correction factors used for a specific condenser application and its operating range, there could be substantial deviations in predicted condenser performance and associated impact on output. Using a case study, this paper examines the use of the correction factors from the seventh and ninth editions in power plant condenser performance predictions. It provides recommendations for developing proper benchmarks and for ensuring optimum condenser performance.
Skip Nav Destination
ASME 2006 Power Conference
May 2–4, 2006
Atlanta, Georgia, USA
Conference Sponsors:
- Power Division
ISBN:
0-7918-4205-3
PROCEEDINGS PAPER
Deviations in Predicted Condenser Performance for Power Plants Using HEI Correction Factors: A Case Study
Komandur S. Sunder Raj
Komandur S. Sunder Raj
Power & Energy Systems Services, Oradell, NJ
Search for other works by this author on:
Komandur S. Sunder Raj
Power & Energy Systems Services, Oradell, NJ
Paper No:
POWER2006-88003, pp. 127-135; 9 pages
Published Online:
October 7, 2008
Citation
Sunder Raj, KS. "Deviations in Predicted Condenser Performance for Power Plants Using HEI Correction Factors: A Case Study." Proceedings of the ASME 2006 Power Conference. ASME 2006 Power Conference. Atlanta, Georgia, USA. May 2–4, 2006. pp. 127-135. ASME. https://doi.org/10.1115/POWER2006-88003
Download citation file:
8
Views
Related Proceedings Papers
Related Articles
Deviations in Predicted Condenser Performance for Power Plants Using HEI Correction Factors: A Case Study
J. Eng. Gas Turbines Power (March,2008)
Corrosion of Feedwater Heater Tubing Alloys in Peaking Service
J. Eng. Power (July,1965)
Condenser Tube Materials for Seawater Service
J. Eng. Power (October,1966)
Related Chapters
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Threshold Functions
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Engineering and Physical Modeling of Power Plant Cooling Systems
Thermal Power Plant Cooling: Context and Engineering