Firstly analyzes the generator parameters of air-gap magnetomotive force, magnetic permeability, magnetic flux density, the stator winding parallel-connected branches electromotive force distribution, and gets voltage difference and circulating current expressions between stator winding parallel-connected branches. Secondly, through analyzing the parameters changing on normal operation and fault condition, the circulating current characteristics are given based on the expressions, which are that hasn’t the circulating current when generator operates normally, and second harmonic circulating current will increase when the rotor winding inter-turn short circuit fault has happened, and fundamental circulating current will increase when stator winding inter-turn short circuit or air-gap eccentricity fault has happened. Considering that different fault has different circulating current characteristic, the generator fault diagnosis method based on circulating current was developed. Finally practically acquires SDF-9 generator data on the fault, the results of verification show that analysis is correct.
Skip Nav Destination
ASME 2005 Power Conference
April 5–7, 2005
Chicago, Illinois, USA
Conference Sponsors:
- Power Division
ISBN:
0-7918-4182-0
PROCEEDINGS PAPER
Analysis of Turbo-Generator Circulating Current Between Stator Winding Parallel-Connected Branches Under Fault Conditions
Shuting Wan,
Shuting Wan
North China Electric Power University, Baoding, Hebei, China
Search for other works by this author on:
Heming Li,
Heming Li
North China Electric Power University, Baoding, Hebei, China
Search for other works by this author on:
Yonggang Li,
Yonggang Li
North China Electric Power University, Baoding, Hebei, China
Search for other works by this author on:
Fanchao Meng
Fanchao Meng
North China Electric Power University, Baoding, Hebei, China
Search for other works by this author on:
Shuting Wan
North China Electric Power University, Baoding, Hebei, China
Heming Li
North China Electric Power University, Baoding, Hebei, China
Yonggang Li
North China Electric Power University, Baoding, Hebei, China
Fanchao Meng
North China Electric Power University, Baoding, Hebei, China
Paper No:
PWR2005-50046, pp. 411-415; 5 pages
Published Online:
October 27, 2008
Citation
Wan, S, Li, H, Li, Y, & Meng, F. "Analysis of Turbo-Generator Circulating Current Between Stator Winding Parallel-Connected Branches Under Fault Conditions." Proceedings of the ASME 2005 Power Conference. ASME 2005 Power Conference. Chicago, Illinois, USA. April 5–7, 2005. pp. 411-415. ASME. https://doi.org/10.1115/PWR2005-50046
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
Low Cycle Fatigue Life of Turbine Generator Retaining Rings Determined by Stress Cycling Tests
J. Basic Eng (March,1965)
Demonstration of a Palm-Sized 30 W Air-to-Power Turbine Generator
J. Eng. Gas Turbines Power (October,2011)
Characteristics of the Convective Heat Transfer Coefficient at the End Winding of a Hydro Generator
J. Thermal Sci. Eng. Appl (March,2015)
Related Chapters
Analysis on Double Resonances of Generator Stator and Rotor Coupling Rigid Model
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
Formulation and Dynamic Behavior of Electrical Systems
Introduction to Dynamics and Control in Mechanical Engineering Systems
Improving Dynamic Performance of Wind Farms in a Distribution System Using DSTATCOM
International Conference on Software Technology and Engineering, 3rd (ICSTE 2011)