Cooling water intake problems come in many forms. These problems can include large schools of fish or jellyfish, seaweed, lake grass, sand, and silt buildup or carryover in the cooling water intake and screen house. Lower lake levels and higher average temperatures, zebra mussel infestation, and non-uniform flow rates between traveling water screen (TWS) bays and circulating water pump bays due to under-sized intake structures can also affect cooling water intake. Downstream of the cooling water intake, flow imbalances caused by entrained debris challenge heat exchanger designs and aging equipment. One Midwestern plant developed an integrated approach to improve the overall performance of the cooling water intake which will result in increased operating efficiency. For the subject plant, this paper will discuss specific modifications planned or undertaken and their benefits and limitations, flow modeling and design margin analyses completed and in process, anticipated reduction in debris carryover, impingement, and entrainment, and suggested further improvements. The majority of modifications undertaken or planned at the subject plant are generally intended to minimize debris carryover and to reduce problems associated with system blockages and heat exchanger tube fouling. Specific modifications to be discussed include: an acoustic fish deterrent system at the inlet tunnel entrance, replacement of the flow-through TWS’s with an industry first-of-a-kind design screen technology, screen wash, and debris transport and removal system modifications, service water system strainer basket modifications, service water system heat exchanger repairs and modifications, and installation of a sodium hypochlorite system.
Skip Nav Destination
ASME 2005 Power Conference
April 5–7, 2005
Chicago, Illinois, USA
Conference Sponsors:
- Power Division
ISBN:
0-7918-4182-0
PROCEEDINGS PAPER
An Integrated Cooling Water Intake System Enhancement Strategy
Jeffrey M. Jones,
Jeffrey M. Jones
Framatome ANP, Inc., Charlotte, NC
Search for other works by this author on:
Bert Mayer
Bert Mayer
Framatome ANP, Inc., Marlborough, MA
Search for other works by this author on:
Jeffrey M. Jones
Framatome ANP, Inc., Charlotte, NC
Bert Mayer
Framatome ANP, Inc., Marlborough, MA
Paper No:
PWR2005-50061, pp. 29-33; 5 pages
Published Online:
October 27, 2008
Citation
Jones, JM, & Mayer, B. "An Integrated Cooling Water Intake System Enhancement Strategy." Proceedings of the ASME 2005 Power Conference. ASME 2005 Power Conference. Chicago, Illinois, USA. April 5–7, 2005. pp. 29-33. ASME. https://doi.org/10.1115/PWR2005-50061
Download citation file:
12
Views
Related Articles
RELAP5-3D Three-Dimensional Analysis Based on PHÉNIX Dissymmetric Transient Test
ASME J of Nuclear Rad Sci (January,2020)
Efficiency Improvement of Photovoltaic Solar Modules by Cooling Using an Underground Heat Exchanger
J. Sol. Energy Eng (December,2022)
A Modified Analysis of Counter Flow Wet Cooling Towers
J. Heat Transfer (August,1997)
Related Chapters
Pipeline Integrity and Security
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Engineering and Physical Modeling of Power Plant Cooling Systems
Thermal Power Plant Cooling: Context and Engineering
Research of Jingzhou City Circumvallation Park Plan
International Conference on Optimization Design (ICOD 2010)