Military personnel working in high noise environments can be exposed to continuous noise levels up to 150 dB. United States (US) Department of Defense (DoD) Hearing Conservation Programs (HCPs) [1–3] set safe noise exposure limits to reduce the risk for noise induced hearing loss. These daily noise exposure limits were based on ambient noise levels and the duration of time spent in that noise environment. Current dosimeters, worn on the lapel of personnel and at least one system worn under a hearing protector, were designed to measure noise levels and calculate noise dose, but do not provide a validated measure of noise dose external to or under a hearing protector. Noise dose under hearing protectors can be estimated by subtracting the real ear attenuation (REAT) data, collected in accordance with the American National Standards Institute (ANSI) S12.6 [4], at each octave band from the ambient octave band noise. This procedure gives accurate results for group data, but does not account for individual variations in effective attenuation. To address this issue, the US Naval Air Systems Command (NAVAIR) led the development of ship suitable in-ear dosimetry integrated into a hearing protector, and co-sponsored an effort executed by the Air Force Research Laboratory (AFRL) to calibrate in-ear noise dose readings. This was accomplished by conducting human noise exposure experiments, with and without hearing protection, which calculated noise dose from temporary threshold shifts (TTS) in hearing. Ten subjects participated in the study. Noise levels were 91, 94, and 97 dB for up to 2 hrs, 1 hr, and 30 minutes respectively. These exposure levels were well within US DoD safe noise exposure guidelines (DoD HCP) [1–3]. Data will be presented describing the open and occluded (protected) ear TTS response to noise dose achieved by subjects in the experiment. Preliminary findings indicate that human subject data is extremely important in developing and validating calibration factors for any type of noise dosimeter but is especially important for in-ear dosimetry. Results from this study demonstrated that the REAT noise dose estimations and the in-ear dosimetry earplugs consistently overestimated the effective noise dose received by subjects. However, more than 10 subjects are required to improve the confidence level of the estimated calibration factor.
Skip Nav Destination
ASME 2012 Noise Control and Acoustics Division Conference at InterNoise 2012
August 19–22, 2012
New York City, New York, USA
Conference Sponsors:
- Noise Control and Acoustics Division
ISBN:
978-0-7918-4532-5
PROCEEDINGS PAPER
Hearing Protection With Integrated In-Ear Dosimetry: A Noise Dose Study
Melissa A. Theis,
Melissa A. Theis
Oak Ridge Institute for Science and Education, Oak Ridge, TN
Search for other works by this author on:
Hilary L. Gallagher,
Hilary L. Gallagher
Air Force Research Laboratory, WPAFB, OH
Search for other works by this author on:
Richard L. McKinley,
Richard L. McKinley
Air Force Research Laboratory, WPAFB, OH
Search for other works by this author on:
Valerie S. Bjorn
Valerie S. Bjorn
Naval Air Systems Command, Arnold AFB, TN
Search for other works by this author on:
Melissa A. Theis
Oak Ridge Institute for Science and Education, Oak Ridge, TN
Hilary L. Gallagher
Air Force Research Laboratory, WPAFB, OH
Richard L. McKinley
Air Force Research Laboratory, WPAFB, OH
Valerie S. Bjorn
Naval Air Systems Command, Arnold AFB, TN
Paper No:
NCAD2012-0636, pp. 237-241; 5 pages
Published Online:
September 10, 2013
Citation
Theis, MA, Gallagher, HL, McKinley, RL, & Bjorn, VS. "Hearing Protection With Integrated In-Ear Dosimetry: A Noise Dose Study." Proceedings of the ASME 2012 Noise Control and Acoustics Division Conference at InterNoise 2012. ASME 2012 Noise Control and Acoustics Division Conference. New York City, New York, USA. August 19–22, 2012. pp. 237-241. ASME. https://doi.org/10.1115/NCAD2012-0636
Download citation file:
33
Views
Related Proceedings Papers
Related Articles
The Next Century of Air Power
Mechanical Engineering (November,2003)
Suppressing the Infrared Signatures of Marine Gas Turbines
J. Eng. Gas Turbines Power (January,1989)
The Use of Polycarbonate as Dosimeter of High Doses
ASME J of Nuclear Rad Sci (April,2021)
Related Chapters
Modular Architecting for Effects Based Operations
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17
Application of Risk Methods to Assess Air Force Capabilities (PSAM-0084)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Introduction
Development of Reliability-Based Load and Resistance Factor Design (LRFD) Methods for Piping