Percutaneous medical procedures rely upon clinicians performing precise needle insertion in soft tissue. The utility of haptic simulation systems in training clinicians for these procedures is highly dependent upon the ability to render accurate insertion force feedback. This paper presents a piecewise mathematical model for insertion force that does not require tissue material properties, detailed mechanical approximations, or complex computations. With manipulation of model parameters, a wide variety of insertion tasks and clinical scenarios can be modeled. Through needle insertion experiments and parameter estimation, this model was demonstrated to replicate the insertion forces associated with a variety of needle and tissue types. In 11 of 12 needle and tissue combinations tested, the model replicated the insertion force with an average absolute mean error of less than 0.065 N.
Skip Nav Destination
ASME 2015 International Manufacturing Science and Engineering Conference
June 8–12, 2015
Charlotte, North Carolina, USA
Conference Sponsors:
- Manufacturing Engineering Division
ISBN:
978-0-7918-5683-3
PROCEEDINGS PAPER
Needle Insertion Force Model for Haptic Simulation
Adam Gordon,
Adam Gordon
The Pennsylvania State University, University Park, PA
Search for other works by this author on:
Inki Kim,
Inki Kim
The Pennsylvania State University, University Park, PA
Search for other works by this author on:
Andrew C. Barnett,
Andrew C. Barnett
The Pennsylvania State University, University Park, PA
Search for other works by this author on:
Jason Z. Moore
Jason Z. Moore
The Pennsylvania State University, University Park, PA
Search for other works by this author on:
Adam Gordon
The Pennsylvania State University, University Park, PA
Inki Kim
The Pennsylvania State University, University Park, PA
Andrew C. Barnett
The Pennsylvania State University, University Park, PA
Jason Z. Moore
The Pennsylvania State University, University Park, PA
Paper No:
MSEC2015-9352, V002T03A003; 8 pages
Published Online:
September 25, 2015
Citation
Gordon, A, Kim, I, Barnett, AC, & Moore, JZ. "Needle Insertion Force Model for Haptic Simulation." Proceedings of the ASME 2015 International Manufacturing Science and Engineering Conference. Volume 2: Materials; Biomanufacturing; Properties, Applications and Systems; Sustainable Manufacturing. Charlotte, North Carolina, USA. June 8–12, 2015. V002T03A003. ASME. https://doi.org/10.1115/MSEC2015-9352
Download citation file:
64
Views
Related Proceedings Papers
Data Driven Development of Haptic Models for Needle Biopsy Phantoms
DSCC2012-MOVIC2012
Related Articles
Mechanical Characterization of Anisotropic Planar Biological Soft
Tissues Using Large Indentation: A Computational Feasibility
Study
J Biomech Eng (June,2006)
Smooth Anatomical Models From 3D Imaging
J. Med. Devices (June,2009)
A Compact and Modular Laparoscopic Grasper With Tridirectional Force Measurement Capability
J. Med. Devices (September,2008)
Related Chapters
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
K-Models Clustering, a Generalization of K-Means Clustering
Intelligent Engineering Systems through Artificial Neural Networks, Volume 20
Surface Analysis and Tools
Tribology of Mechanical Systems: A Guide to Present and Future Technologies