This paper utilized SiC thin film deposited by low temperature PECVD to fabricate resonator at 300°C, following by annealing and doping to release its stress and improve its electronics contact. The test results show that, the frequency of PECVD SiC resonator is among 60–150KHz. The Q value of resonator was estimated according to the tested frequency-amplitude curve, is about 10±3. The ability of SiC resonators in erosion environment was also studied, under 5mins etching in KOH solution, the whole structure are kept very well. Therefore, this kind PECVD SiC resonator not only can be used widely in harsh environment, such as, high temperature, erosion and high pressure, but also can integrated with CMOS process, release the integration manufacturing of circuit and devices in micro-scale.
Skip Nav Destination
2007 First International Conference on Integration and Commercialization of Micro and Nanosystems
January 10–13, 2007
Sanya, Hainan, China
Conference Sponsors:
- Nanotechnology Institute
ISBN:
0-7918-4265-7
PROCEEDINGS PAPER
Fabrication and Test of PECVD SiC Resonator
Haixia Zhang,
Haixia Zhang
Peking University, Beijing, China
Search for other works by this author on:
Guobing Zhang,
Guobing Zhang
Peking University, Beijing, China
Search for other works by this author on:
Zhihong Li
Zhihong Li
Peking University, Beijing, China
Search for other works by this author on:
Yu Wang
Peking University, Beijing, China
Hui Guo
Peking University, Beijing, China
Haixia Zhang
Peking University, Beijing, China
Guobing Zhang
Peking University, Beijing, China
Zhihong Li
Peking University, Beijing, China
Paper No:
MNC2007-21240, pp. 455-458; 4 pages
Published Online:
June 8, 2009
Citation
Wang, Y, Guo, H, Zhang, H, Zhang, G, & Li, Z. "Fabrication and Test of PECVD SiC Resonator." Proceedings of the 2007 First International Conference on Integration and Commercialization of Micro and Nanosystems. First International Conference on Integration and Commercialization of Micro and Nanosystems, Parts A and B. Sanya, Hainan, China. January 10–13, 2007. pp. 455-458. ASME. https://doi.org/10.1115/MNC2007-21240
Download citation file:
5
Views
Related Proceedings Papers
Related Articles
Development of Nanoporous Ultrathin Membranes For Implantable Drug Delivery
J. Med. Devices (June,2008)
Size Effects on the Thermodynamic Properties of Thin Solid Films
J. Heat Transfer (November,1998)
Focused Ion-Beam Based Nanohole Modeling, Simulation, Fabrication, and Application
J. Manuf. Sci. Eng (February,2010)
Related Chapters
Multi-Channel Constant Current LED Driver with PWM Boost Converter
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
Study of Effectiveness of Circuit Level Leakage Power Optimization Techniques in DSM CMOS Cells
International Conference on Software Technology and Engineering, 3rd (ICSTE 2011)
On the Evaluation of Thermal and Mechanical Factors in Low-Speed Sliding
Tribology of Mechanical Systems: A Guide to Present and Future Technologies