Flexible electronics have a myriad of potential applications in fields such as healthcare, soldier situational awareness, soldier rehabilitation, sports performance, and textile manufacturing among other areas. The primary benefits that flexible electronics provide to both the producers and consumers are their light weight, low power consumption, efficiency, low cost of production, flexibility, and scalability. In comparison to rigid electronics, these systems would be subjected to a greater amount of mechanical and thermal stress in real-time due to their ability to be flexed, rolled, folded, and stretched. Environmental conditions such as bending, mechanical shock, water immersion, sweat, UV radiation, and temperature exposure could degrade the performance of these embedded electronic systems. At this time, there is a lack of suitable test standards and reliability data about flexible electronics manufacturing, assembly, and real-time use. In this paper, a fully flexible medical electronics system was built in full dimension to study the assembly and operation-related failure mechanisms of flexible and wearable electronics. The fabricated flexible electronics system measures pulse and muscle activity, and then transmits this data to a paired mobile device. The pulse rate was measured using an LED and a photo diode, while an electromyography (EMG) sensor was used to measure muscle activity. After collecting the data, the microcontroller sends it to a Bluetooth module, which can in turn transmit this information to a paired mobile device. Through experimentation with the fabricated flexible electronics device, unexpected degradation and quality issues were observed. In flexible PCBs, the space between the IC lead could not be isolated by the solder mask because of its large feature size and as a result, increases the risk of shortage between IC leads when subjected to mechanical stress. In addition, during the assembly process, high reflow temperature was found to subject a huge thermal stress on the connections between the solder pad and copper trace. Proper support of the solder pad should be designed to compensate the thermal stress during the reflow process, and prevent the copper joint on top of the board from being damaged. A set of guidelines for flexible medical electronics and an implementable reliability test standard can, therefore, be established for medical device manufacturers based on these reliability assessments.
Skip Nav Destination
ASME 2017 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems collocated with the ASME 2017 Conference on Information Storage and Processing Systems
August 29–September 1, 2017
San Francisco, California, USA
Conference Sponsors:
- Electronic and Photonic Packaging Division
ISBN:
978-0-7918-5809-7
PROCEEDINGS PAPER
Design and Development of Biometric Sensor Wearable Band Using Flexible Electronics
Rahul Lall
Rahul Lall
Stanford University, Stanford, CA
Search for other works by this author on:
Pradeep Lall
Auburn University, Auburn, AL
Hao Zhang
Auburn University, Auburn, AL
Rahul Lall
Stanford University, Stanford, CA
Paper No:
IPACK2017-74232, V001T03A002; 10 pages
Published Online:
October 27, 2017
Citation
Lall, P, Zhang, H, & Lall, R. "Design and Development of Biometric Sensor Wearable Band Using Flexible Electronics." Proceedings of the ASME 2017 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems collocated with the ASME 2017 Conference on Information Storage and Processing Systems. ASME 2017 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems. San Francisco, California, USA. August 29–September 1, 2017. V001T03A002. ASME. https://doi.org/10.1115/IPACK2017-74232
Download citation file:
65
Views
Related Proceedings Papers
Related Articles
Special Section on InterPACK 2013
J. Electron. Packag (December,2014)
Ubiquitous Health Monitoring System for Diagnosis of Sleep Apnea With Zigbee Network and Wireless LAN
J. Nanotechnol. Eng. Med (May,2011)
Harnessing Experience for Efficient Medical Device Product Development
J. Med. Devices (June,2009)
Related Chapters
A Human Reliability-Centered Approach to the Development of Job Aids for Reviewers of Medical Devices That Use Radiological Byproduct Materials (PSAM-0299)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Integrity Management of Critical Systems Introduction
Asset Integrity Management of Critical Infrastructure
Fabrication of MSM UV Detector Using ZnO Nanowires
International Conference on Computer and Electrical Engineering 4th (ICCEE 2011)