When converting an electric power by an insulated-gate bipolar transistor (IGBT) module, the problem which is the heat generation in the IGBT module should be prudently considered in the design process. As an engineer reviews the cooling performance of power semi-conductor devices only at the component level, it is difficult to predict the reduction of airflow rates in the heat sink when power semi-conductor devices including the heat sink are integrated into the power conversion system. As the porous media model is adopted in the IGBT stack of the PCS, the problem that the meshes are heavily concentrated in the IGBT module including the heat sink, air, and IGBT/diode chips can be evaded and the airflow rate which is reflected in the effect of flow resistance by all interior structures including the IGBT module is calculated. For the outdoor type PCS, the hotspot temperature on the heat sink of the simulation and experiment is 99.3 and 101.6 Celsius, respectively. The proposed numerical simulation model considerably accurately predicts the hotspot temperature on the heat sink and can earn benefits in terms of efforts of mesh generation and computation time.
Skip Nav Destination
ASME 2015 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems collocated with the ASME 2015 13th International Conference on Nanochannels, Microchannels, and Minichannels
July 6–9, 2015
San Francisco, California, USA
Conference Sponsors:
- Electronic and Photonic Packaging Division
ISBN:
978-0-7918-5688-8
PROCEEDINGS PAPER
A Study on the Thermo-Fluid Simulation Model Using Porous Media in the Power Conversion System
Chang-Woo Han,
Chang-Woo Han
Hyosung Corporation, Anyang-si, Korea
Search for other works by this author on:
You-Lim Moon,
You-Lim Moon
Hyosung Corporation, Anyang-si, Korea
Search for other works by this author on:
Seung-Boong Jeong,
Seung-Boong Jeong
Hyosung Corporation, Anyang-si, Korea
Search for other works by this author on:
Jong-Hee Han
Jong-Hee Han
Hyosung Corporation, Anyang-si, Korea
Search for other works by this author on:
Chang-Woo Han
Hyosung Corporation, Anyang-si, Korea
You-Lim Moon
Hyosung Corporation, Anyang-si, Korea
Seung-Boong Jeong
Hyosung Corporation, Anyang-si, Korea
Jong-Hee Han
Hyosung Corporation, Anyang-si, Korea
Paper No:
IPACK2015-48085, V001T09A001; 7 pages
Published Online:
November 19, 2015
Citation
Han, C, Moon, Y, Jeong, S, & Han, J. "A Study on the Thermo-Fluid Simulation Model Using Porous Media in the Power Conversion System." Proceedings of the ASME 2015 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems collocated with the ASME 2015 13th International Conference on Nanochannels, Microchannels, and Minichannels. Volume 1: Thermal Management. San Francisco, California, USA. July 6–9, 2015. V001T09A001. ASME. https://doi.org/10.1115/IPACK2015-48085
Download citation file:
26
Views
Related Proceedings Papers
Advanced Cooling Designs for GaN-on-Diamond MMICs
InterPACK2015
Related Articles
Vapor Chamber Acting as a Heat Spreader for Power Module Cooling
J. Thermal Sci. Eng. Appl (June,2009)
A Wire-Bondless Packaging Platform for Silicon Carbide Power Semiconductor Devices
J. Electron. Packag (September,2018)
Numerical Prediction of Flow and Heat Transfer in an Impingement Heat
Sink
J. Electron. Packag (March,1997)
Related Chapters
Low Power and Low Area Analog Multiplier Using MiFGMOS
International Conference on Computer and Automation Engineering, 4th (ICCAE 2012)
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Spice Model on High Frequency Vibration for CMUT Application
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3