The Syracuse/IBM Green Data Center utilizes micro turbines in combination with exhaust fired heat exchangers and absorption chillers to produce electrical power, cooling and heating for the data center and surrounding infrastructure. The overall efficiency of cogeneration systems depend greatly on the utilization of turbine exhaust heat. This makes a data center (where cooling load and electrical power requirements are closely correlated) an excellent candidate for cogeneration technology. Over 200 data points collected in the data center allow for in-depth energy analysis of this unique data center and the surrounding infrastructure. This paper provides information on the Syracuse/IBM Green Data Center systems as well as analysis of the data center over all four seasons. In addition to PUE, the common data center metric, a new metric defined as ERE1 is used to measure data center efficiency when energy is exported to the surrounding infrastructure.
Skip Nav Destination
ASME 2013 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems
July 16–18, 2013
Burlingame, California, USA
Conference Sponsors:
- Electronic and Photonic Packaging Division
ISBN:
978-0-7918-5576-8
PROCEEDINGS PAPER
Assessment of the Energy Performance of Cogeneration Systems for Powering and Cooling Data Centers
Dale C. Ringham,
Dale C. Ringham
Syracuse University, Syracuse, NY
Search for other works by this author on:
Dan J. Rice,
Dan J. Rice
Syracuse University, Syracuse, NY
Search for other works by this author on:
Brian S. Granetz,
Brian S. Granetz
Syracuse University, Syracuse, NY
Search for other works by this author on:
Hamza Salih Erden,
Hamza Salih Erden
Syracuse University, Syracuse, NY
Search for other works by this author on:
H. Ezzat Khalifa,
H. Ezzat Khalifa
Syracuse University, Syracuse, NY
Search for other works by this author on:
Roger R. Schmidt
Roger R. Schmidt
IBM Corporation, Poughkeepsie, NY
Search for other works by this author on:
Dale C. Ringham
Syracuse University, Syracuse, NY
Dan J. Rice
Syracuse University, Syracuse, NY
Brian S. Granetz
Syracuse University, Syracuse, NY
Hamza Salih Erden
Syracuse University, Syracuse, NY
H. Ezzat Khalifa
Syracuse University, Syracuse, NY
Roger R. Schmidt
IBM Corporation, Poughkeepsie, NY
Paper No:
IPACK2013-73268, V002T09A022; 7 pages
Published Online:
January 20, 2014
Citation
Ringham, DC, Rice, DJ, Granetz, BS, Erden, HS, Khalifa, HE, & Schmidt, RR. "Assessment of the Energy Performance of Cogeneration Systems for Powering and Cooling Data Centers." Proceedings of the ASME 2013 International Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Microsystems. Volume 2: Thermal Management; Data Centers and Energy Efficient Electronic Systems. Burlingame, California, USA. July 16–18, 2013. V002T09A022. ASME. https://doi.org/10.1115/IPACK2013-73268
Download citation file:
19
Views
Related Proceedings Papers
Related Articles
Compact Diesel Engine Waste-Heat-Driven Ammonia–Water Absorption Heat Pump Modeling and Performance Maximization Strategies
J. Energy Resour. Technol (June,2022)
Cogeneration System Simulation and Control to Meet Simultaneous Power, Heating, and Cooling Demands
J. Eng. Gas Turbines Power (April,2005)
Related Chapters
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Engineering and Physical Modeling of Power Plant Cooling Systems
Thermal Power Plant Cooling: Context and Engineering