As the energy footprint of data centers continues to increase, models that allow for “what-if” simulations of different data center design and management paradigms will be important. Prior work by the authors has described a multi-scale energy efficiency model that allows for evaluating the coefficient of performance of the data center ensemble (COPGrand), and demonstrated the utility of such a model for purposes of choosing operational set-points and evaluating design trade-offs. However, experimental validation of these models poses a challenge because of the complexity involved with tailoring such a model for implementation to legacy data centers, with shared infrastructure and limited control over IT workload. Further, test facilities with dummy heat loads or artificial racks in lieu of IT equipment generally have limited utility in validating end-to-end models owing to the inability of such loads to mimic phenomena such as fan scalability, etc. In this work, we describe the experimental analysis conducted in a special test chamber and data center facility. The chamber, focusing on system level effects, is loaded with an actual IT rack, and a compressor delivers chilled air to the chamber at a preset temperature. By varying the load in the IT rack as well as the air delivery parameters — such as flow rate, supply temperature, etc. — a setup which simulates the system level of a data center is created. Experimental tests within a live data center facility are also conducted where the operating conditions of the cooling infrastructure are monitored — such as fluid temperatures, flow rates, etc. — and can be analyzed to determine effects such as air flow recirculation, heat exchanger performance, etc. Using the experimental data a multi-scale model configuration emulating the data center can be defined. We compare the results from such experimental analysis to a multi-scale energy efficiency model of the data center, and discuss the accuracies as well as inaccuracies within such a model. Difficulties encountered in the experimental work are discussed. The paper concludes by discussing areas for improvement in such modeling and experimental evaluation. Further validation of the complete multi-scale data center energy model is planned.
Skip Nav Destination
ASME 2011 Pacific Rim Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Systems
July 6–8, 2011
Portland, Oregon, USA
Conference Sponsors:
- Electronic and Photonic Packaging Division
ISBN:
978-0-7918-4462-5
PROCEEDINGS PAPER
Influence of Experimental Uncertainty on Prediction of Holistic Multi-Scale Data Center Energy Efficiency
Thomas J. Breen,
Thomas J. Breen
Stokes Institute, University of Limerick, Limerick, Ireland
Search for other works by this author on:
Ed J. Walsh,
Ed J. Walsh
Stokes Institute, University of Limerick, Limerick, Ireland
Search for other works by this author on:
Jeff Punch,
Jeff Punch
Stokes Institute, University of Limerick, Limerick, Ireland
Search for other works by this author on:
Amip J. Shah,
Amip J. Shah
Hewlett Packard Company, Palo Alto, CA
Search for other works by this author on:
Niru Kumari,
Niru Kumari
Hewlett Packard Company, Palo Alto, CA
Search for other works by this author on:
Cullen E. Bash,
Cullen E. Bash
Hewlett Packard Company, Palo Alto, CA
Search for other works by this author on:
Scot Heath,
Scot Heath
Hewlett Packard Company, Fort Collins, CO
Search for other works by this author on:
Brandon Rubenstein
Brandon Rubenstein
Hewlett Packard Company, Fort Collins, CO
Search for other works by this author on:
Thomas J. Breen
Stokes Institute, University of Limerick, Limerick, Ireland
Ed J. Walsh
Stokes Institute, University of Limerick, Limerick, Ireland
Jeff Punch
Stokes Institute, University of Limerick, Limerick, Ireland
Amip J. Shah
Hewlett Packard Company, Palo Alto, CA
Niru Kumari
Hewlett Packard Company, Palo Alto, CA
Cullen E. Bash
Hewlett Packard Company, Palo Alto, CA
Scot Heath
Hewlett Packard Company, Fort Collins, CO
Brandon Rubenstein
Hewlett Packard Company, Fort Collins, CO
Paper No:
IPACK2011-52141, pp. 553-563; 11 pages
Published Online:
February 14, 2012
Citation
Breen, TJ, Walsh, EJ, Punch, J, Shah, AJ, Kumari, N, Bash, CE, Heath, S, & Rubenstein, B. "Influence of Experimental Uncertainty on Prediction of Holistic Multi-Scale Data Center Energy Efficiency." Proceedings of the ASME 2011 Pacific Rim Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Systems. ASME 2011 Pacific Rim Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Systems, MEMS and NEMS: Volume 2. Portland, Oregon, USA. July 6–8, 2011. pp. 553-563. ASME. https://doi.org/10.1115/IPACK2011-52141
Download citation file:
8
Views
Related Proceedings Papers
Related Articles
Experimental and Computational Investigations of the Thermal Environment in a Small Operational Data Center for Potential Energy Efficiency Improvements
J. Electron. Packag (September,2020)
Ultra-Compact Microscale Heat Exchanger for Advanced Thermal Management in Data Centers
J. Electron. Packag (June,2022)
Gas Turbine Arekret-Cycle Simulation Modeling for Training and Educational Purposes
ASME J of Nuclear Rad Sci (October,2019)
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Advances in the Stochastic Modeling of Constitutive Laws at Small and Finite Strains
Advances in Computers and Information in Engineering Research, Volume 2
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential