The work presented in this paper describes a simplified thermodynamic model that can be used for exploring optimization possibilities in air-cooled data centers. The model is used to parametrically evaluate the total energy consumption of the data center cooling infrastructure for data centers that utilize aisle containment. The analysis highlights the importance of reducing the total power required for moving the air within the CRACs, the plenum, and the servers, rather than focusing primarily or exclusively on reducing the refrigeration system’s power consumption and shows the benefits of bypass recirculation in enclosed aisle configurations. The analysis shows a potential for as much as a 57% savings in cooling infrastructure energy consumption by utilizing an optimized enclosed aisle configuration with bypass recirculation, instead of a traditional enclosed aisle, where all the data center exhaust is forced to flow through the computer room air conditioners (CRACs), for racks with a modest temperature rise (∼10°C). However, for racks with larger temperature rise (> ∼20°C), the saving are less than 5%. Furthermore, for servers whose fan speed (flow rate) varies as a function of inlet temperature, the analysis shows that the optimum operating regime for enclosed aisle data centers falls within a very narrow band and that power reductions are possible by lowering the uniform server inlet temperature in the enclosed aisle from 27°C to 22°C. However, the optimum CRAC exit temperature over the 22-to-27°C range of enclosed cold aisle temperature falls between ∼16 and 20°C because a significant reduction in the power consumption is possible through the use of bypass recirculation. Without bypass recirculation, the power consumption for a server inlet temperature of 22°C enclosed aisle case with a server temperature rise of 10°C would be a whopping 43% higher than with bypass recirculation. It is worth noting that, without bypass recirculation maintaining the enclosed cold aisle at 22°C instead of 27°C would reduce power consumption by 48%. It is also shown that enclosing the aisles together with bypass recirculation (when beneficial) also reduces the dependence of the optimum cooling power on server temperature rise.
Skip Nav Destination
ASME 2011 Pacific Rim Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Systems
July 6–8, 2011
Portland, Oregon, USA
Conference Sponsors:
- Electronic and Photonic Packaging Division
ISBN:
978-0-7918-4462-5
PROCEEDINGS PAPER
Energy Modeling of Air-Cooled Data Centers: Part I—The Optimization of Enclosed Aisle Configurations
Dustin W. Demetriou,
Dustin W. Demetriou
Syracuse University, Syracuse, NY
Search for other works by this author on:
H. Ezzat Khalifa
H. Ezzat Khalifa
Syracuse University, Syracuse, NY
Search for other works by this author on:
Dustin W. Demetriou
Syracuse University, Syracuse, NY
H. Ezzat Khalifa
Syracuse University, Syracuse, NY
Paper No:
IPACK2011-52003, pp. 385-394; 10 pages
Published Online:
February 14, 2012
Citation
Demetriou, DW, & Khalifa, HE. "Energy Modeling of Air-Cooled Data Centers: Part I—The Optimization of Enclosed Aisle Configurations." Proceedings of the ASME 2011 Pacific Rim Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Systems. ASME 2011 Pacific Rim Technical Conference and Exhibition on Packaging and Integration of Electronic and Photonic Systems, MEMS and NEMS: Volume 2. Portland, Oregon, USA. July 6–8, 2011. pp. 385-394. ASME. https://doi.org/10.1115/IPACK2011-52003
Download citation file:
19
Views
Related Proceedings Papers
Related Articles
A Simulation-Based Approach to Data Center Thermal Efficiency Optimization
J. Eng. Sustain. Bldgs. Cities (February,2020)
Simulation-Based Assessment of Performance Indicator for Data Center Cooling Optimization
J. Thermal Sci. Eng. Appl (October,2020)
Optimization of Enclosed Aisle Data Centers Using Bypass Recirculation
J. Electron. Packag (June,2012)
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Optimization of Contact Search Policy in Wireless Mobile Ad Hoc Networks
International Conference on Software Technology and Engineering, 3rd (ICSTE 2011)
Engineering and Physical Modeling of Power Plant Cooling Systems
Thermal Power Plant Cooling: Context and Engineering