Energy consumption and energy prices are two critical concerns for data center operators. In 2005, servers alone accounted for 1.2% of energy consumption in the U.S. [1]. By 2012, the EPA predicts energy consumption in data centers will double from 2007 levels. Energy prices are also increasing. In 2006, they rose by 10% [1]. Energy prices are expected to rise even higher, due to regulatory and social concerns over green house gas emissions from energy production. In this work, we demonstrate how data center energy consumption can be reduced and thermal capacity improved by systematically considering the interactions between data center infrastructure elements (e.g., cooling and servers). Specifically, we quantify the benefits of the automated migration of workloads running in Virtual Machines (VMs). VMs are migrated from a set of servers located in an inefficient thermal zone to servers in a more efficient zone. Our experimental results show that our technique reduced data center energy usage by 30% and improved available thermal capacity by 22%.
Skip Nav Destination
ASME 2009 InterPACK Conference collocated with the ASME 2009 Summer Heat Transfer Conference and the ASME 2009 3rd International Conference on Energy Sustainability
July 19–23, 2009
San Francisco, California, USA
Conference Sponsors:
- Electronic and Photonic Packaging Division
ISBN:
978-0-7918-4360-4
PROCEEDINGS PAPER
Thermal Policies and Active Workload Migration Within Data Centers
Cullen Bash,
Cullen Bash
Hewlett-Packard Labs, Palo Alto, CA
Search for other works by this author on:
Chris Hyser,
Chris Hyser
Hewlett-Packard Labs, Palo Alto, CA
Search for other works by this author on:
Christopher Hoover
Christopher Hoover
Hewlett-Packard Labs, Palo Alto, CA
Search for other works by this author on:
Cullen Bash
Hewlett-Packard Labs, Palo Alto, CA
Chris Hyser
Hewlett-Packard Labs, Palo Alto, CA
Christopher Hoover
Hewlett-Packard Labs, Palo Alto, CA
Paper No:
InterPACK2009-89038, pp. 673-679; 7 pages
Published Online:
December 24, 2010
Citation
Bash, C, Hyser, C, & Hoover, C. "Thermal Policies and Active Workload Migration Within Data Centers." Proceedings of the ASME 2009 InterPACK Conference collocated with the ASME 2009 Summer Heat Transfer Conference and the ASME 2009 3rd International Conference on Energy Sustainability. ASME 2009 InterPACK Conference, Volume 2. San Francisco, California, USA. July 19–23, 2009. pp. 673-679. ASME. https://doi.org/10.1115/InterPACK2009-89038
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
Measurement of the Heat Capacity of Copper Thin Films Using a Micropulse Calorimeter
J. Heat Transfer (January,2010)
Energy Optimization of
Air-Cooled Data Centers
J. Thermal Sci. Eng. Appl (December,2010)
Analytical Modeling for Thermodynamic Characterization of Data Center Cooling Systems
J. Electron. Packag (June,2009)
Related Chapters
The Special Characteristics of Closed-Cycle Gas Turbines
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Studies Performed
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Preserving Nuclear Power's Place in a Balanced Power Generation Policy
Energy and Power Generation Handbook: Established and Emerging Technologies