In this paper we address the high level of validation of commercially available numerical predictive tools, namely CFD models, for data center applications. Experimental data at a real world facility is compared with computational results. Specifically, a recently developed temperature measurement tool is used to capture three dimensional temperature profiles of the facility with very fine spatial granularity. These detailed contours based on actual measurements reveal hot air recirculation patterns in the room as well as variable utilization levels of the room air-conditioning units. We compare these experimental temperature distributions measured using a novel 3D mapping tool with CFD thermal modeling results. An algorithm for generating CFD models for real world systems is proposed and demonstrated. It is found that due to the extensive inaccuracies in rapidly gathered input data as well as inherent limitations of the model, there can be significant discrepancies between predicted and actual temperatures. In addition to steady state measurements, transient data was also collected and are presented. Knowledge of the transient temperature profiles at different parts of the room allows an estimation of the temporal behavior of the data center. Transient temperature fluctuations are presented which capture the real variations in the system boundary conditions, for example the temperature of the chilled water to the air conditioning units, or the power dissipation of the servers over time.
Skip Nav Destination
ASME 2007 InterPACK Conference collocated with the ASME/JSME 2007 Thermal Engineering Heat Transfer Summer Conference
July 8–12, 2007
Vancouver, British Columbia, Canada
Conference Sponsors:
- Electronic and Photonic Packaging Division
ISBN:
0-7918-4277-0
PROCEEDINGS PAPER
Comparison of Experimental Temperature Results With Numerical Modeling Predictions of a Real-World Compact Data Center Facility
Madhusudan Iyengar,
Madhusudan Iyengar
IBM, Poughkeepsie, NY
Search for other works by this author on:
Michael Schappert,
Michael Schappert
IBM, Yorktown Heights, NY
Search for other works by this author on:
Theodore van Kessel
Theodore van Kessel
IBM, Yorktown Heights, NY
Search for other works by this author on:
Yasuo Amemiya
IBM, Yorktown Heights, NY
Madhusudan Iyengar
IBM, Poughkeepsie, NY
Hendrik Hamann
IBM, Yorktown Heights, NY
Martin O’Boyle
IBM, Yorktown Heights, NY
Michael Schappert
IBM, Yorktown Heights, NY
Jing Shen
IBM, Yorktown Heights, NY
Theodore van Kessel
IBM, Yorktown Heights, NY
Paper No:
IPACK2007-33899, pp. 871-876; 6 pages
Published Online:
January 8, 2010
Citation
Amemiya, Y, Iyengar, M, Hamann, H, O’Boyle, M, Schappert, M, Shen, J, & van Kessel, T. "Comparison of Experimental Temperature Results With Numerical Modeling Predictions of a Real-World Compact Data Center Facility." Proceedings of the ASME 2007 InterPACK Conference collocated with the ASME/JSME 2007 Thermal Engineering Heat Transfer Summer Conference. ASME 2007 InterPACK Conference, Volume 1. Vancouver, British Columbia, Canada. July 8–12, 2007. pp. 871-876. ASME. https://doi.org/10.1115/IPACK2007-33899
Download citation file:
10
Views
Related Proceedings Papers
Related Articles
An Efficient Localized Radial Basis Function Meshless Method for Fluid Flow and Conjugate Heat Transfer
J. Heat Transfer (February,2007)
Experimental and Numerical Study of Mixing in a Hot-Water Storage Tank
J. Sol. Energy Eng (February,2009)
Related Chapters
CMA1-2 Based on Coordinate Transformation
International Conference on Electronics, Information and Communication Engineering (EICE 2012)
The Localized Collocation Meshless Method (LCMM) Framework
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
Virtualization of Data Centers and Optimization of Resource Allocation in It, by Extra Innovative Algorithms
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3