Capillary pumped loop has been widely investigated for space thermal control devices. This cooling device with high reliability and thermal controllability is also considered to be suited to cool electronic devices like personal computers. Because the capillary pumped loop is good at absorbing heat from high heat flux region like micro-processors, transporting it and releasing it from the large surface for packaging. In this research, the experimental equipment of the capillary pumped loop was manufactured. The experimental apparatus consists of the evaporator, the condenser, the liquid line, the vapor line and the reservoir. In the experiments heat load is applied to the evaporator by a resistance heater. And heat is released from the condenser to the cooling water which is set to be a constant temperature by the refrigerator. The length and the diameter of the evaporator are 150mm and 27mm respectively and the capillary wick with equivalent diameter of 5μm is embedded in the evaporator. These specifications were designed to give 2500mm heat transport distance and to adapt the natural convection heat transfer to the ambient without a cooling fan. As is proposed in the recent study, the inside of the capillary wick was used as the reservoir to simplify the loop. In our previous study, the heat transport characteristics in steady states were investigated when the heat flux, the cooling water temperature and the evaporator height above the condenser changed, and then the effects of enclosed rate of the working fluid in the reservoir and the inclination angles of the evaporator on heat transport rate were investigated. The computer code was also developed to simulate the heat transport characteristics and evaluate the maximum heat transport rate of the tested capillary pump. In the next step, we focus on the dynamic characteristics. The heat loads of the micro-processors in the computers usually change according to the working conditions of the application software and vary hourly. Thus the active thermal regulation accompanied with the change of heat loads is the important factor for cooling devices in the computers. So in this study the heat transport characteristics in the dynamic conditions of the capillary pumped loop were investigated. In the experiment, the start-up and shut-down mode at a given heat load were tested at first. Then heat load were changed in incremental or decremental steps from 30 to 70W. All results show the good thermal controllability.
Skip Nav Destination
ASME 2007 InterPACK Conference collocated with the ASME/JSME 2007 Thermal Engineering Heat Transfer Summer Conference
July 8–12, 2007
Vancouver, British Columbia, Canada
Conference Sponsors:
- Electronic and Photonic Packaging Division
ISBN:
0-7918-4277-0
PROCEEDINGS PAPER
Dynamic Characteristics of the Capillary Pumped Loop for Cooling the Tower-Type Computer
Atsushi Tsujimori,
Atsushi Tsujimori
Kanto-Gakuin University, Yokohama, Kanagawa, Japan
Search for other works by this author on:
Masashi Kato,
Masashi Kato
Kanto-Gakuin University, Yokohama, Kanagawa, Japan
Search for other works by this author on:
Maiko Uchida
Maiko Uchida
Kanto-Gakuin University, Yokohama, Kanagawa, Japan
Search for other works by this author on:
Atsushi Tsujimori
Kanto-Gakuin University, Yokohama, Kanagawa, Japan
Masashi Kato
Kanto-Gakuin University, Yokohama, Kanagawa, Japan
Maiko Uchida
Kanto-Gakuin University, Yokohama, Kanagawa, Japan
Paper No:
IPACK2007-33161, pp. 663-668; 6 pages
Published Online:
January 8, 2010
Citation
Tsujimori, A, Kato, M, & Uchida, M. "Dynamic Characteristics of the Capillary Pumped Loop for Cooling the Tower-Type Computer." Proceedings of the ASME 2007 InterPACK Conference collocated with the ASME/JSME 2007 Thermal Engineering Heat Transfer Summer Conference. ASME 2007 InterPACK Conference, Volume 1. Vancouver, British Columbia, Canada. July 8–12, 2007. pp. 663-668. ASME. https://doi.org/10.1115/IPACK2007-33161
Download citation file:
5
Views
Related Proceedings Papers
Related Articles
Foreword
J. Heat Transfer (January,2005)
Thermal Design of an Airborne Computer Chassis With Air-Cooled, Cast Pin Fin Coldwalls
J. Heat Transfer (January,2005)
Evaluation of an Interstitial Cooling Device for Carotid Arterial Cooling Using a Tissue Equivalent Gel Phantom
J. Thermal Sci. Eng. Appl (March,2010)
Related Chapters
Computer Simulation of Road-Vehicle Dynamic Interaction Forces of Three- and Four-Axle Trucks
Vehicle-Road Interaction
Tribological Models for Solid/Solid Contact: Missing Links
Tribological Modeling for Mechanical Designers
Generation and Use of Composite Material Data Bases
Computerization and Networking of Materials Data Bases