The design of a thermal management system for an airborne, infrared, optical telescope system is described. This system provides transient thermal management for the optical elements of the system beginning at a high-temperature soak condition of 71°C (159.8°F) on the ground to a low-temperature operating condition of −30°C (−22°F) to −40°C (−40° F) within 45 min after aircraft takeoff. An active cooling system is employed to enable this rapid cooldown. In addition to the low-temperature requirement, the mirrors and lenses must be cooled so that temperature gradients across the optical elements are on the order of 1°C (33.8 °F) to 2°C (35.6 °F). The ambient air available for ground cooling is specified by the military environment to be 55°C (131.0 °F). As the aircraft takes off and climbs to an altitude of 11,582.4 m (38 kft), the ambient air temperature decreases to a low-temperature of −22°C (−7.6 °F) for steady, level flight at at Mach 0.9, this ambient air temperature results in a ram air inlet temperature on the order of 13.5°C (56.3 °F), after the air is captured and diffused to Mach 0.2 prior to entry into a ram air heat exchanger. This ram air heat sink is used to provide a chilled liquid for cooling of optical elements and the turret housing the system. The low temperatures required for this system, which are on the order of −30°C (−22 °F) to −40°C (−40 °F), make the use of forced-convection, liquid-cooling problematic because of the tendancy of liquids to become quite viscous as they approach these low temperature levels. Furthermore, the use of a single-phase heat transfer process will result in temperature gradients within the system. For these reasons, cooling concepts employing single-phase cooling using chilled-liquids have been eliminated from consideration. A low-temperature, low-pressure refrigerant, R-404a, is used as the working fluid. The themal management system uses the optical elements as the evaporator of a two-phase cooling system. The liquid refrigerant is introduced into the optical elements at the saturation temperature and saturation pressure of the liquid. The flow rate of the refrigerant will be controlled in such a manner that all of the heat transfer takes place in the liquid-vapor mixture region of the thermodynamic diagram for R-404a with the refrigerant exiting the elements at an arbitraily determned quality of approximately 0.8. This will assure that all of the heat transfer will be by boiling heat transfer and will take place at a constant temperature and essentially a constant pressure. Since the heat transfer coefficients are large and the process takes place at essentially a constant temperature, the optical elements will be controlled at the saturation temperature of the refrigerant and will be essentially a constant temperature across the expanse of the optical surface. The thermal management system is comprised of an array of TECs configured as a condenser HX. This TEC HX uses ram air as the eventual heat sink and will provide chilled-liquid produced by a liquid-to-ram air HX as the heat sink for the hot side of the TEC array. This system utilizes the system mass as the evaporator and a TEC HX as the condenser in a two-phase heat transfer process to provide rapid cooldown of the system mass to low temperatures in a short period of time and maintain that mass at proper operating temperatures with essentially zero temperature gradients throughout the system.
Skip Nav Destination
ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems collocated with the ASME 2005 Heat Transfer Summer Conference
July 17–22, 2005
San Francisco, California, USA
Conference Sponsors:
- Heat Transfer Division and Electronic and Photonic Packaging Division
ISBN:
0-7918-4200-2
PROCEEDINGS PAPER
Design of a Transient, Temperature Control System for a Low-Temperature Infrared Optical Telescope Utilizing a Ramai R-Cooled Thermoelectric Assembly as the Condenser of a Two-Phase Cooling System
Donald C. Price,
Donald C. Price
Raytheon Company, McKinney, TX
Search for other works by this author on:
W. Gerald Wyatt,
W. Gerald Wyatt
Raytheon Company, McKinney, TX
Search for other works by this author on:
Pete Townsend,
Pete Townsend
Marlow Industries, Dallas, TX
Search for other works by this author on:
Mark C. Woods,
Mark C. Woods
Marlow Industries, Dallas, TX
Search for other works by this author on:
Brad W. Fennell
Brad W. Fennell
Raytheon Company, McKinney, TX
Search for other works by this author on:
Donald C. Price
Raytheon Company, McKinney, TX
W. Gerald Wyatt
Raytheon Company, McKinney, TX
Pete Townsend
Marlow Industries, Dallas, TX
Mark C. Woods
Marlow Industries, Dallas, TX
Brad W. Fennell
Raytheon Company, McKinney, TX
Paper No:
IPACK2005-73496, pp. 683-695; 13 pages
Published Online:
March 4, 2009
Citation
Price, DC, Wyatt, WG, Townsend, P, Woods, MC, & Fennell, BW. "Design of a Transient, Temperature Control System for a Low-Temperature Infrared Optical Telescope Utilizing a Ramai R-Cooled Thermoelectric Assembly as the Condenser of a Two-Phase Cooling System." Proceedings of the ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems collocated with the ASME 2005 Heat Transfer Summer Conference. Advances in Electronic Packaging, Parts A, B, and C. San Francisco, California, USA. July 17–22, 2005. pp. 683-695. ASME. https://doi.org/10.1115/IPACK2005-73496
Download citation file:
9
Views
Related Proceedings Papers
Capacity Control in Refrigerated Systems
InterPACK2003
Related Articles
Ultra-Compact Microscale Heat Exchanger for Advanced Thermal Management in Data Centers
J. Electron. Packag (June,2022)
High-Flux Thermal Management With Supercritical Fluids
J. Heat Transfer (December,2016)
A Vapotron Effect Application for Electronic Equipment Cooling
J. Electron. Packag (December,2003)
Related Chapters
Engineering and Physical Modeling of Power Plant Cooling Systems
Thermal Power Plant Cooling: Context and Engineering
Thermoelectric Coolers
Thermal Management of Microelectronic Equipment
Thermal Design Guide of Liquid Cooled Systems
Thermal Design of Liquid Cooled Microelectronic Equipment