The heat dissipated by electronic equipment continues to increase at a alarming rate. This has occurred for products covering a wide range of applications. Manufacturers of this equipment require that the equipment be maintained within an environmental envelope in order to guarantee proper operation. Achievement of these environmental conditions are becoming increasingly difficult given the increases in rack heat loads and the desire for customers of such equipment to cluster racks in a small region for increased performance. And with the increased heat load of the racks and correspondingly increased air flowrate the chilled air flow supplied either through data center raised floor perforated tiles or diffusers for non raised floors is not sufficient to match the air flow required by the datacom racks. In this case some of the hot air exhausting the rear of a rack can return to the front of the rack and be ingested into the air intake thereby reducing the reliability of the electronic equipment. This paper describes a method to reduce the effect of the hot air recirculation with a water cooled heat exchanger attached to the rear door of the rack. This heat exchanger removes a large portion of the heat from the rack as well as significantly lowering the air temperature exhausting the rear of the rack. This paper describes the hardware and presents the test results showing that a large portion of the heat is removed from the rack and the temperature exhausting the rear of the rack is significantly reduced. Finally the effectiveness of the solution is shown in modeling of this water cooled solution in a data center application.
Skip Nav Destination
ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems collocated with the ASME 2005 Heat Transfer Summer Conference
July 17–22, 2005
San Francisco, California, USA
Conference Sponsors:
- Heat Transfer Division and Electronic and Photonic Packaging Division
ISBN:
0-7918-4200-2
PROCEEDINGS PAPER
Maintaining Datacom Rack Inlet Air Temperatures With Water Cooled Heat Exchanger
Roger Schmidt,
Roger Schmidt
IBM Corporation, Poughkeepsie, NY
Search for other works by this author on:
Richard C. Chu,
Richard C. Chu
IBM Corporation, Poughkeepsie, NY
Search for other works by this author on:
Mike Ellsworth,
Mike Ellsworth
IBM Corporation, Poughkeepsie, NY
Search for other works by this author on:
Madhu Iyengar,
Madhu Iyengar
IBM Corporation, Poughkeepsie, NY
Search for other works by this author on:
Vinod Kamath,
Vinod Kamath
IBM Corporation, Research Triangle Park, NC
Search for other works by this author on:
Bret Lehman
Bret Lehman
IBM Corporation, Research Triangle Park, NC
Search for other works by this author on:
Roger Schmidt
IBM Corporation, Poughkeepsie, NY
Richard C. Chu
IBM Corporation, Poughkeepsie, NY
Mike Ellsworth
IBM Corporation, Poughkeepsie, NY
Madhu Iyengar
IBM Corporation, Poughkeepsie, NY
Don Porter
IBM Corporation, Poughkeepsie, NY
Vinod Kamath
IBM Corporation, Research Triangle Park, NC
Bret Lehman
IBM Corporation, Research Triangle Park, NC
Paper No:
IPACK2005-73468, pp. 663-673; 11 pages
Published Online:
March 4, 2009
Citation
Schmidt, R, Chu, RC, Ellsworth, M, Iyengar, M, Porter, D, Kamath, V, & Lehman, B. "Maintaining Datacom Rack Inlet Air Temperatures With Water Cooled Heat Exchanger." Proceedings of the ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems collocated with the ASME 2005 Heat Transfer Summer Conference. Advances in Electronic Packaging, Parts A, B, and C. San Francisco, California, USA. July 17–22, 2005. pp. 663-673. ASME. https://doi.org/10.1115/IPACK2005-73468
Download citation file:
22
Views
Related Proceedings Papers
Related Articles
Steady State and Transient Experimentally Validated Analysis of Hybrid Data Centers
J. Electron. Packag (June,2015)
Characterization of a Rack-Level Thermosyphon-Based Cooling System
J. Electron. Packag (September,2024)
Performance Analysis of Liquid-to-Air Heat Exchanger of High-Power Density Racks
J. Electron. Packag (December,2024)
Related Chapters
The Localized Collocation Meshless Method (LCMM) Framework
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
The Finite-Differencing Enhanced LCMM
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
Virtualization of Data Centers and Optimization of Resource Allocation in It, by Extra Innovative Algorithms
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3