In a typical raised floor data center with alternating hot and cold aisles, air enters the front of each rack over the entire height of the rack. Since the heat loads of data processing equipment continues to increase at a rapid rate, it is a challenge to maintain the temperature within the requirements as stated for all the racks within the data center. A facility manager has discretion in deciding the data center room layout, but a wrong decision will eventually lead to equipment failure. There are many complex decisions to be made early in the design as the data center evolves. Challenges occur such as optimizing the raised floor plenum, floor tile placement, minimizing the data center local hot spots etc. These adjustments in configuration affects rack inlet air temperatures which is one of the important key to effective thermal management. In this paper, a raised floor data center with 4.5 kW racks is considered. There are four rows of racks with alternating hot and cold aisle arrangement. Each row has six racks installed. Two CRAC units supply chilled air to the data center through the pressurized plenum. Effect of plenum depth, floor tile placement and ceiling height on the rack inlet air temperature is discussed. Plots will be presented over the defined range. Now a multi-variable approach to optimize data center room layout to minimize the rack inlet air temperature is proposed. Significant improvement over the initial model is shown by using multi-variable design optimization approach. The results of multi-variable design optimization are used to present guidelines for optimal data center performance.
Skip Nav Destination
ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems collocated with the ASME 2005 Heat Transfer Summer Conference
July 17–22, 2005
San Francisco, California, USA
Conference Sponsors:
- Heat Transfer Division and Electronic and Photonic Packaging Division
ISBN:
0-7918-4200-2
PROCEEDINGS PAPER
Optimization of Data Center Room Layout to Minimize Rack Inlet Air Temperature
Siddharth Bhopte,
Siddharth Bhopte
University of Texas at Arlington, Arlington, TX
Search for other works by this author on:
Dereje Agonafer,
Dereje Agonafer
University of Texas at Arlington, Arlington, TX
Search for other works by this author on:
Roger Schmidt,
Roger Schmidt
IBM Corporation, Poughkeepsie, NY
Search for other works by this author on:
Bahgat Sammakia
Bahgat Sammakia
State University of New York at Binghamton, Binghamton, NY
Search for other works by this author on:
Siddharth Bhopte
University of Texas at Arlington, Arlington, TX
Dereje Agonafer
University of Texas at Arlington, Arlington, TX
Roger Schmidt
IBM Corporation, Poughkeepsie, NY
Bahgat Sammakia
State University of New York at Binghamton, Binghamton, NY
Paper No:
IPACK2005-73027, pp. 33-41; 9 pages
Published Online:
March 4, 2009
Citation
Bhopte, S, Agonafer, D, Schmidt, R, & Sammakia, B. "Optimization of Data Center Room Layout to Minimize Rack Inlet Air Temperature." Proceedings of the ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems collocated with the ASME 2005 Heat Transfer Summer Conference. Advances in Electronic Packaging, Parts A, B, and C. San Francisco, California, USA. July 17–22, 2005. pp. 33-41. ASME. https://doi.org/10.1115/IPACK2005-73027
Download citation file:
23
Views
Related Proceedings Papers
Related Articles
Viability of Dynamic Cooling Control in a Data Center
Environment
J. Electron. Packag (June,2006)
A Comparison of Parametric and Multivariable Optimization Techniques in a Raised-Floor Data Center
J. Electron. Packag (September,2013)
Thermal Management Issues in Operational Data Centers: Computational Fluid Dynamics Analysis and Experimental Study
J. Thermal Sci. Eng. Appl (September,2017)
Related Chapters
Prediction of Failures in Service by Photoelastic Methods
Advanced Testing Techniques
The Finite-Differencing Enhanced LCMM
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
Virtualization of Data Centers and Optimization of Resource Allocation in It, by Extra Innovative Algorithms
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3