Processor powers of 30–60W are becoming very common in electronic industry. With constraints such as available heat sink space and the cost of the thermal solution, heat sink optimization has become one of the major concerns in the final design process. In this work two (new) strategies are proposed along with the traditional heat sink optimization process (i.e. fin/base thickness and fin spacing optimization). First, heat pipes are embedded into the aluminum base extruded heat sink to reduce spreading resistance. The resulting heat sink is more efficient and even cheaper when compared to the bounded-fin technology on a copper base. Second, the angled base modification is introduced to reduce the spreading resistance in the flow direction. It is observed that up to 5 degrees angle in the base can reduce the thermal resistance of an active heat sink by 8–10%.
Skip Nav Destination
ASME 2003 International Electronic Packaging Technical Conference and Exhibition
July 6–11, 2003
Maui, Hawaii, USA
Conference Sponsors:
- Electronic and Photonic Packaging Division
ISBN:
0-7918-3690-8
PROCEEDINGS PAPER
Cooling Solution for Next Generation High-Power Processor Boards in 1U Computer Servers
Farzam Roknaldin,
Farzam Roknaldin
Applied Thermal Technologies, Santa Clara, CA
Search for other works by this author on:
Ridvan A. Sahan
Ridvan A. Sahan
Fluent, Inc., Santa Clara, CA
Search for other works by this author on:
Farzam Roknaldin
Applied Thermal Technologies, Santa Clara, CA
Ridvan A. Sahan
Fluent, Inc., Santa Clara, CA
Paper No:
IPACK2003-35294, pp. 629-634; 6 pages
Published Online:
January 5, 2009
Citation
Roknaldin, F, & Sahan, RA. "Cooling Solution for Next Generation High-Power Processor Boards in 1U Computer Servers." Proceedings of the ASME 2003 International Electronic Packaging Technical Conference and Exhibition. 2003 International Electronic Packaging Technical Conference and Exhibition, Volume 2. Maui, Hawaii, USA. July 6–11, 2003. pp. 629-634. ASME. https://doi.org/10.1115/IPACK2003-35294
Download citation file:
10
Views
Related Proceedings Papers
Related Articles
A Simplified Conduction Based Modeling Scheme for Design Sensitivity Study of Thermal Solution Utilizing Heat Pipe and Vapor Chamber Technology
J. Electron. Packag (September,2003)
Multiple Fan-Heat Sink Cooling System With Enhanced Evaporator Base: Design, Modeling, and Experiment
J. Electron. Packag (September,2009)
Thermal Interfacing Techniques for Electronic Equipment—A Perspective
J. Electron. Packag (June,2003)
Related Chapters
System Thermal Analysis-Rack (Part II)
Thermal Management of Telecommunication Equipment, Second Edition
When Is a Heat Sink Not a Heat Sink?
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong