The Florida Solar Energy Center (FSEC) has partnered with Sandia National Laboratories (SNL), the Southwest Technical Development Institute (SWTDI), and the California Energy Commissions Public Interest Energy Research (CEC PIER) in an effort to characterize the performance of PV inverters operating over extended periods of time. As part of this characterization, SNL executed an initial performance characterization in the laboratory to be repeated at one or two year intervals. These inverters were then sent distributed to the above test facilities for installation and long-term testing. To perform this long-term testing, FSEC built an inverter test facility made up of a configurable 10.1 kW PV array and four test beds. Each test bed was set up to monitor the following parameters: DC voltage, DC current, AC Voltage, AC Power and inverter temperature. Solar irradiance, ambient temperature, and several PV array temperatures were recorded by a separate, synchronized datalogger. Three inverters are currently being tested: the Fronius IG 3000, the Xantrex GT 3.0, and the SMA Sunny Boy 2500U. The three inverters were loaded with a PV array close to the maximum power limit allowed by the inverter, and the array power supplied to each inverter was within 100 W of one another. Since the PV array for each inverter used identical PV modules mounted in the same orientation, it was easier to develop a model to compare inverter performance based on energy output. In addition to energy output, other parameters were obtained such as inverter efficiency. An attempt was made to compare the results obtained at FSEC to those results compiled by the California Energy Commission.
Skip Nav Destination
ASME 2006 International Solar Energy Conference
July 8–13, 2006
Denver, Colorado, USA
Conference Sponsors:
- Solar Energy Division
ISBN:
0-7918-4745-4
PROCEEDINGS PAPER
Early Results From the Long-Term Testing of Inverters
Kevin Lynn,
Kevin Lynn
Florida Solar Energy Center, Cocoa, FL
Search for other works by this author on:
William Wilson
William Wilson
Florida Solar Energy Center, Cocoa, FL
Search for other works by this author on:
Kevin Lynn
Florida Solar Energy Center, Cocoa, FL
William Wilson
Florida Solar Energy Center, Cocoa, FL
Paper No:
ISEC2006-99111, pp. 149-151; 3 pages
Published Online:
October 2, 2008
Citation
Lynn, K, & Wilson, W. "Early Results From the Long-Term Testing of Inverters." Proceedings of the ASME 2006 International Solar Energy Conference. Solar Energy. Denver, Colorado, USA. July 8–13, 2006. pp. 149-151. ASME. https://doi.org/10.1115/ISEC2006-99111
Download citation file:
6
Views
Related Proceedings Papers
Related Articles
Solar Steam Reforming of Methane in a Volumetric Receiver–Reactor With Different Types of Catalysts
J. Sol. Energy Eng (November,2012)
Comparative Performance and Model Agreement of Three Common Photovoltaic Array Configurations
J. Sol. Energy Eng (February,2018)
Measured Performance of Building Integrated Photovoltaic Panels—Round 2
J. Sol. Energy Eng (August,2005)
Related Chapters
Performance Characteristics of Combined Solar Photovoltaic and Thermal System for Brackish Water Desalination
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Output Characteristics, Statistics, and Calculation Examples of Taguchi Methods
Taguchi Methods: Benefits, Impacts, Mathematics, Statistics and Applications
Energy Balance for a Swimming Pool
Electromagnetic Waves and Heat Transfer: Sensitivites to Governing Variables in Everyday Life