Venting and evaporative cooling are modeled as possible techniques for protecting polymer absorbers in single-glazed, flat-plate solar collectors from exceeding the material temperature limit during dry stagnation. Four venting options are considered: I) venting above the absorber plate, II) venting below, III) dual venting, and IV) venting with evaporative cooling. Results indicate that in hot, sunny conditions, venting may not provide adequate cooling to lower the absorber temperature to the relative thermal index of the polymeric materials currently in use or under consideration for this application. Venting combined with evaporative cooling from a wetted pad directly beneath the absorber plate is identified as a potential method of overheat protection in hot, dry climates.
Skip Nav Destination
ASME 2005 International Solar Energy Conference
August 6–12, 2005
Orlando, Florida, USA
Conference Sponsors:
- Solar Energy Division
ISBN:
0-7918-4737-3
PROCEEDINGS PAPER
Polymeric Absorbers for Flat Plate Collectors: Can Venting Provide Adequate Overheat Protection?
Meghan Kearney,
Meghan Kearney
University of Minnesota, Minneapolis, MN
Search for other works by this author on:
Jane H. Davidson,
Jane H. Davidson
University of Minnesota, Minneapolis, MN
Search for other works by this author on:
Susan Mantell
Susan Mantell
University of Minnesota, Minneapolis, MN
Search for other works by this author on:
Meghan Kearney
University of Minnesota, Minneapolis, MN
Jane H. Davidson
University of Minnesota, Minneapolis, MN
Susan Mantell
University of Minnesota, Minneapolis, MN
Paper No:
ISEC2005-76005, pp. 253-257; 5 pages
Published Online:
October 15, 2008
Citation
Kearney, M, Davidson, JH, & Mantell, S. "Polymeric Absorbers for Flat Plate Collectors: Can Venting Provide Adequate Overheat Protection?." Proceedings of the ASME 2005 International Solar Energy Conference. Solar Energy. Orlando, Florida, USA. August 6–12, 2005. pp. 253-257. ASME. https://doi.org/10.1115/ISEC2005-76005
Download citation file:
2
Views
Related Proceedings Papers
Related Articles
Polymeric Absorbers for Flat-Plate Collectors: Can Venting Provide Adequate Overheat Protection?
J. Sol. Energy Eng (August,2005)
Climatic Effect on the Exergetic Performance of Conventional to Hybrid Evaporative Coolers With Varying Dead-State Temperatures in India
J. Thermal Sci. Eng. Appl (May,2022)
Latent Heat Fluxes Through Soft Materials With Microtruss Architectures
J. Heat Transfer (April,2008)
Related Chapters
Dynamic Cool Roofing Systems
Advanced Energy Efficient Building Envelope Systems
Economic Considerations and Drivers
Thermal Power Plant Cooling: Context and Engineering
The Impact of Plant Economics on the Design of Industrial Energy Systems
Industrial Energy Systems