The performance analysis of Turbine - Type and Ultrasonic natural gas flowmeters installed in series in the same stream. The instruments were connected to flow computers for a period of 18 months. During this time all measured differences between the Ultrasonic flowmeter and the Turbine flowmeter were recorded. The performance between instruments is presented in graphs. Throughout this time all system maintenance events were recorded.