The purpose of emergency shut-down valves (ESDVs) is to provide the capability of dividing sour gas pipelines into segments, which can be individually isolated during upsets or ruptures by closure of the ESDVs. CIMARRON Engineering Ltd. (CIMARRON) performed a study in 2003 to evaluate installing ESDVs below ground for sour gas pipelines. The direct burial advantages of easier pigging, reduction in pipeline stresses, smaller surface footprint, less visibility, lower installation and maintenance costs, less chance of vandalism, and less chance of unauthorized operation are all desirable. This direct burial option, using weld neck valves, is contrary to the conventional above ground installation with flanged valves, which dominates the practice in Western Canada. CIMARRON has used the criteria of feasibility, benefits, and limitations in evaluating the option of direct burial. To these three (3) criteria have been added measures to mitigate any identify limitations or constraints. In addition, piggability for cleaning and in-line inspection is considered to be a required feature for all sour gas pipelines. CIMARRON has reviewed and gathered extensive field data and background case studies for the preparation of this paper. In addition to the industry standard of above ground ESDVs, they are also occasionally installed in vaults. However, entry into any vault constitutes a “confined space entry” with its associated implications on safety. CIMARRON contends that if certain capabilities are provided for functional access from the surface to a buried ESDV, then compliance with all requirements of the governing legislation is possible without being able to physically see or access the buried valve. Enhancements to the responsiveness of ESDVs to pipeline upsets and failures are important. Using SCADA at both wellsites and ESDV sites can provide a significant advantage in limiting any potential sour gas releases. The simplifications associated with buried ESDVs can constitute a significant advantage. Taking all these aspects into consideration, there are substantial benefits to burying ESDVs when compared to both the above ground and vaulted options.
Skip Nav Destination
2004 International Pipeline Conference
October 4–8, 2004
Calgary, Alberta, Canada
Conference Sponsors:
- International Petroleum Technology Institute
ISBN:
0-7918-4176-6
PROCEEDINGS PAPER
Evaluation of Below Ground Emergency Shutdown Valves in Sour Gas Pipelines Available to Purchase
Guy M. Shulhan
Guy M. Shulhan
CIMARRON Engineering Ltd., Calgary, AB, Canada
Search for other works by this author on:
Guy M. Shulhan
CIMARRON Engineering Ltd., Calgary, AB, Canada
Paper No:
IPC2004-0263, pp. 2071-2088; 18 pages
Published Online:
December 4, 2008
Citation
Shulhan, GM. "Evaluation of Below Ground Emergency Shutdown Valves in Sour Gas Pipelines." Proceedings of the 2004 International Pipeline Conference. 2004 International Pipeline Conference, Volumes 1, 2, and 3. Calgary, Alberta, Canada. October 4–8, 2004. pp. 2071-2088. ASME. https://doi.org/10.1115/IPC2004-0263
Download citation file:
10
Views
Related Proceedings Papers
Related Articles
Investigation of a Large High- Speed Diesel Engine Transient Behavior Including Compressor Surging and Emergency Shutdown
J. Eng. Gas Turbines Power (April,2003)
Behavior of X60 Line Pipe Subjected to Axial and Lateral Deformations
J. Pressure Vessel Technol (June,2010)
Measurement of Decompression Wave Speed in Rich Gas Mixtures at High Pressures (370 bars) Using a Specialized Rupture Tube
J. Pressure Vessel Technol (October,2010)
Related Chapters
Description of Rules of Section XII Transport Tank Code
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 2, Fourth Edition
QUANTIFYING SURFACE FAULT RUPTURE HAZARD AT THE ACTIVE FAULT-BURIED PIPELINE INTERSECTION
Pipeline Integrity Management Under Geohazard Conditions (PIMG)
Pipeline Integrity and Security
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards