1-16 of 16
Keywords: ultrasound
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Proc. ASME. IMECE2023, Volume 1: Acoustics, Vibration, and Phononics, V001T01A018, October 29–November 2, 2023
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2023-113926
... (below 100 kHz). Keywords: Ultrasound, optical microphone, MEMS 1. INTRODUCTION Conventional laboratory style measurement microphones are problematic for gathering reliable measurements in the low ultrasonic frequency range (20 100 kHz). High frequency sensitivity is often limited by a microphone s...
Proceedings Papers

Proc. ASME. IMECE2022, Volume 2B: Advanced Manufacturing, V02BT02A048, October 30–November 3, 2022
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2022-94929
... and for sizing the deformities almost 60% accuracy was obtained. 35° and 45° shear waves gave 72% and 43% accurate data respectively. nondestructive evaluation deformity sizing ACT ADDT echo amplitude shear wave normal wave ultrasound Proceedings of the ASME 2022 International Mechanical...
Proceedings Papers

Proc. ASME. IMECE2022, Volume 9: Mechanics of Solids, Structures, and Fluids; Micro- and Nano-Systems Engineering and Packaging; Safety Engineering, Risk, and Reliability Analysis; Research Posters, V009T12A041, October 30–November 3, 2022
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2022-95140
...-section. The parameters utilized for conventional ultrasound techniques were a 5 MHz frequency, a velocity of 0.2320 in/μs and a gain of 30 dB. In phase angle mode, an angle of 45 was utilized. These parameters were optimized and chosen for the calibration of the device with a section of the parent rail...
Proceedings Papers

Proc. ASME. IMECE2022, Volume 1: Acoustics, Vibration, and Phononics, V001T01A040, October 30–November 3, 2022
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2022-96139
... and sensor performance are reported. sensors ultrasound Proceedings of the ASME 2022 International Mechanical Engineering Congress and Exposition IMECE2022 October 30-November 3, 2022, Columbus, Ohio IMECE2022-96139 MICROSCOPIC OPTICAL ACOUSTIC SENSORS FOR INTRACRANIAL MEASUREMENTS David B. Maupin1...
Proceedings Papers

Proc. ASME. IMECE2022, Volume 1: Acoustics, Vibration, and Phononics, V001T01A020, October 30–November 3, 2022
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2022-96236
... AlSi10Mg ultrasound Proceedings of the ASME 2022 International Mechanical Engineering Congress and Exposition IMECE2022 October 30-November 3, 2022, Columbus, Ohio IMECE2022-96236 ULTRASONIC CHARACTERIZATION OF ALSI10MG SPECIMENS PRINTED BY DIRECT ENERGY DEPOSITION TECHNOLOGY Mariya Chukovenkova...
Proceedings Papers

Proc. ASME. IMECE2022, Volume 1: Acoustics, Vibration, and Phononics, V001T01A016, October 30–November 3, 2022
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2022-94931
... for the development of ultrasonic phased array technique for non-destructive evaluation (NDE) of bulky materials. This paper ends with a summary, concluding remarks, and suggestions for future work. nondestructive evaluation damage detection ultrasound phased array reverse time migration Proceedings...
Proceedings Papers

Proc. ASME. IMECE2021, Volume 1: Acoustics, Vibration, and Phononics, V001T01A003, November 1–5, 2021
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2021-70038
... experience high-amplitude vibrations in response to ultrasonic excitation. These methods and results are useful for assessing how a wide variety of devices, including communications equipment, might produce biological effects. ultrasound modal analysis finite element model Proceedings of the ASME...
Proceedings Papers

Proc. ASME. IMECE99, Advances in Heat and Mass Transfer in Biotechnology, 65-69, November 14–19, 1999
Publisher: American Society of Mechanical Engineers
Paper No: IMECE1999-0585
... of these alternative means. Cryosurgery has been used successfully for more than three decades to treat benign and malignant neoplasms. To date, there is one reported case of primary breast cancer treatment with cryotherapy (Staren et al., 1997), which was followed up with ultrasound-guided biopsy, and which was found...
Proceedings Papers

Proc. ASME. IMECE2020, Volume 1: Acoustics, Vibration, and Phononics, V001T01A008, November 16–19, 2020
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2020-24213
... components of the middle and inner ear at ultrasonic frequencies. These “built-in sound amplifiers” can be leveraged to compensate for impedance mismatches experienced in airborne ultrasound transmission. By heterodyning (amplitude modulating) a targeted ultrasonic carrier signal with an audio signal...
Proceedings Papers

Proc. ASME. IMECE2019, Volume 10: Micro- and Nano-Systems Engineering and Packaging, V010T12A012, November 11–14, 2019
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2019-10629
... Abstract This paper presents the innovative integration of both frontier submillimeter magnetic microrobot and integrated ultrasound and photoacoustic (USPA) imaging. The integrative technique will allow for potential real non-invasive microrobot operation in deep biological tissue...
Proceedings Papers

Proc. ASME. IMECE2012, Volume 2: Biomedical and Biotechnology, 941-951, November 9–15, 2012
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2012-89624
..., and to reduce the necessity for performing it, ultrasound elastography was proposed. Elastography is a potential imaging technique to characterize breast masses, and to differentiate malignant from benign lesions, based on imaging estimated tissue strains under compression. This can result in lowering...
Proceedings Papers

Proc. ASME. IMECE2009, Volume 12: Micro and Nano Systems, Parts A and B, 633-641, November 13–19, 2009
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2009-10926
... 08 07 2010 Ultrasound based on-line cleaning for hollow fiber (HF) membrane filtration of synthetic wastewater was studied. An ultrasonic transducer was submerged into a filtration system in order to get an efficient cleaning of HF membranes in fouling conditions. An ultrafiltration...
Proceedings Papers

Proc. ASME. IMECE2009, Volume 9: Heat Transfer, Fluid Flows, and Thermal Systems, Parts A, B and C, 241-249, November 13–19, 2009
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2009-11708
... Ultrasound based on-line cleaning for hollow fiber (HF) membrane filtration of synthetic wastewater was studied. An ultrasonic transducer was submerged into a filtration system in order to get an efficient cleaning of HF membranes in fouling conditions. An ultrafiltration (UF) HF membrane...
Proceedings Papers

Proc. ASME. IMECE2004, Nondestructive Evaluation Engineering, 1-8, November 13–19, 2004
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2004-59700
... in the material and to distinguish special cases of the prestress state, for example, to evaluate quantitatively the parameters of the prestress. ultrasound wave interaction nonlinearity inhomogeneous prestress NDE N E A cs ch m fa in physically nonlinear elastic material undergoing two- para anal...
Proceedings Papers

Proc. ASME. IMECE2004, Nondestructive Evaluation Engineering, 25-29, November 13–19, 2004
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2004-59375
... fractions of microballoons and rubber particles are maintained at 0.63 and 0.02, respectively, in all samples. Pulse Echo ultrasonic test method is used and results are compared to determine the effect of constituent particles on the ultrasound signal attenuation. Coefficient of attenuation is observed...
Proceedings Papers

Proc. ASME. IMECE2005, Manufacturing Engineering and Materials Handling, Parts A and B, 143-150, November 5–11, 2005
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2005-81140
.... In this work, we report on a novel porous polymer fabrication method using high-intensity focused ultrasound (HIFU). The measurements of both spatial and temporal temperature field are reported for biocompatible PMMA (polymethyl methacrylate) samples insonated with a 1.1 MHz/3.3 MHz HIFU transducer...