1-13 of 13
Keywords: calibration
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Proc. ASME. IMECE2023, Volume 7: Energy, V007T08A082, October 29–November 2, 2023
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2023-112430
... are close enough, the models that have generated them are similar. In addition, when simulated and experimental data differ beyond the acceptance criteria, model calibration techniques are used to tweak simulation model parameters to reduce the gap between simulated and experimental data. This gives...
Proceedings Papers

Proc. ASME. IMECE2023, Volume 9: Fluids Engineering, V009T10A032, October 29–November 2, 2023
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2023-115131
.... It was observed that the adjusted new constants achieve more successful results than the default coefficients. By calibrating the model coefficients that differ from the default model coefficients by 16% for 1, 17% for 2, and 1.2% for it is revealed that jet centerline velocity distribution and jet halfwidth...
Proceedings Papers

Proc. ASME. IMECE2022, Volume 2B: Advanced Manufacturing, V02BT02A051, October 30–November 3, 2022
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2022-96010
... for the creation of geometrically complex components, the presence of diverse defects deteriorate the quality of the final build. Defects in FFF (e.g., voids, stringing, and varying track width) are primarily linked to improper calibration of parameters, including feed speed, extrusion speed, extruder temperature...
Proceedings Papers

Proc. ASME. IMECE2022, Volume 8: Fluids Engineering; Heat Transfer and Thermal Engineering, V008T11A061, October 30–November 3, 2022
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2022-95148
... for non-reacting fluids on the microscale level. This paper describes a calibration process and an accuracy test for this novel calorimetry. The test chamber was prefilled with deionized (DI) water (55 μl) and heated to steady state. Then room temperature DI water (15 μl) was injected and was treated...
Proceedings Papers

Proc. ASME. IMECE98, Micro-Electro-Mechanical Systems (MEMS), 11-17, November 15–20, 1998
Publisher: American Society of Mechanical Engineers
Paper No: IMECE1998-1217
... are measures of the three orthogonal components of the force applied at the center of the cross-beam. Calibration of the sensor is achieved by generating electromagnetic forces on an aluminum cross-beam that is suspended over the sensor structure. micro force sensor strain gauge calibration...
Proceedings Papers

Proc. ASME. IMECE99, Heat Transfer: Volume 4, 65-70, November 14–19, 1999
Publisher: American Society of Mechanical Engineers
Paper No: IMECE1999-1104
... Abstract The National Institute of Standards and Technology has developed a convective heat flux facility to allow calibration of heat flux sensors. The facility consists of a small wind tunnel that produces a two-dimensional laminar boundary layer across a heated isothermal copper plate...
Proceedings Papers

Proc. ASME. IMECE2019, Volume 9: Mechanics of Solids, Structures, and Fluids, V009T11A001, November 11–14, 2019
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2019-10521
... modeling approaches, the plug and spot weld, are calibrated, assessed, and compared to a more intensive approach — a “two-block” plug calibrated to multiple datasets. An optimization analysis workflow leveraging a genetic algorithm was exercised on a set of quasistatic test data where fasteners were pulled...
Proceedings Papers

Proc. ASME. IMECE2019, Volume 8: Heat Transfer and Thermal Engineering, V008T09A069, November 11–14, 2019
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2019-11374
... Abstract The accuracy of temperature probe calibration in a constant temperature bath is governed by the stability and uniformity of the bath. In the available literature, there have been efforts in designing baths with better stability and uniformity. This work is distinguished from...
Proceedings Papers

Proc. ASME. IMECE2013, Volume 13: Transportation Systems, V013T14A008, November 15–21, 2013
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2013-62943
... the drivability and for automatic identification of NVH-Phenomena [3] are used to optimize multi criteria objective functions. The measurement is done in the IPEK-X-in-the-Loop Framework (XiL) [4], which enables a transmission assessment on the complete vehicle level. Hybrid-testing calibration...
Proceedings Papers

Proc. ASME. IMECE2008, Volume 13: Nano-Manufacturing Technology; and Micro and Nano Systems, Parts A and B, 181-185, October 31–November 6, 2008
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2008-66561
... 24 08 2009 Sensitivities of microelctromechanical system (MEMS) accelerometers are typically measured and calibrated at final production test of packaged devices. This process typically requires expensive special automated test equipment (ATE) that can generate vibration stimulus...
Proceedings Papers

Proc. ASME. IMECE2005, Manufacturing Engineering and Materials Handling, Parts A and B, 691-697, November 5–11, 2005
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2005-81277
.... Corresponding to the mechanical reconfiguration, the control system also needs to be reconfigured to reflect the actual state of the machine. Mechanical reconfiguration also brings with it the need to verify the accuracy of the new configuration. Also discussed in the paper is the calibration methodology...
Proceedings Papers

Proc. ASME. IMECE2005, Manufacturing Engineering and Materials Handling, Parts A and B, 833-842, November 5–11, 2005
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2005-82893
... 31 01 2008 Cutting force predictions from machining process models are generally accurate to within 20% for a specific tool and work material combination over a wide range of cutting conditions when calibrations are accurately performed. The calibration implicitly assumes that the tool...
Proceedings Papers

Proc. ASME. IMECE2006, Materials, Nondestructive Evaluation, and Pressure Vessels and Piping, 603-610, November 5–10, 2006
Publisher: American Society of Mechanical Engineers
Paper No: IMECE2006-14335
... 18 01 2008 Accurate calibration is required for high-precision mechanical stages used for inspection of mechanical parts. Because of the high cost involved in purchasing and maintaining Coordinate Measuring Machines (CMM), it is common that a dedicated or reconfigurable inspection...