The objective of this study was to assess the effects structural features of endovascular stent-grafts used to repair abdominal aortic aneurysms (AAA) have on the flow mechanics and near-wall hemodynamics using Computational Fluid Dynamics (CFD) simulations. This research compared two test case model representations: 1) a stent graft that included the wire struts in the graft walls, and 2) a stent graft that excluded the struts in the computational mesh. The two computer-aided design models were created to represent a bifurcated stent graft in the abdominal aorta, with the stent beginning in the thoracic region of the aorta and branching into the common iliac arteries. The geometries were imported as surface meshes into a commercially available CFD solver. Both models account for viscous pulsatile blood flow of the cardiac cycle using blood properties gathered from previous research. Results of the two simulations were compared by using established metrics, including oscillating shear index (OSI), time average wall shear stress (TAWSS), and relative residence time (RRT), all of which are used to predict the likelihood of clot formation, endothelial damage, and device failure. Scalar and vector scenes allow for visualization, and data was exported for quantifying threshold results of the parameters. Due to the expense of stent grafts and the risks involved with clinical trial, CFD modeling is becoming more prominent in endovascular repair of aneurysms. The overarching goal of this study is to enhance current models of stent grafts, which can potentially be used to complement clinical trial for stent graft development.
Skip Nav Destination
ASME 2017 International Mechanical Engineering Congress and Exposition
November 3–9, 2017
Tampa, Florida, USA
Conference Sponsors:
- ASME
ISBN:
978-0-7918-5836-3
PROCEEDINGS PAPER
Investigating the Effects of Stent-Graft Structural Features Using Computational Fluid Dynamics
Eric M. Looyenga,
Eric M. Looyenga
South Dakota State University, Brookings, SD
Search for other works by this author on:
Aaron M. Propst,
Aaron M. Propst
South Dakota State University, Brookings, SD
Search for other works by this author on:
Stephen P. Gent
Stephen P. Gent
South Dakota State University, Brookings, SD
Search for other works by this author on:
Eric M. Looyenga
South Dakota State University, Brookings, SD
Aaron M. Propst
South Dakota State University, Brookings, SD
Stephen P. Gent
South Dakota State University, Brookings, SD
Paper No:
IMECE2017-71442, V003T04A024; 9 pages
Published Online:
January 10, 2018
Citation
Looyenga, EM, Propst, AM, & Gent, SP. "Investigating the Effects of Stent-Graft Structural Features Using Computational Fluid Dynamics." Proceedings of the ASME 2017 International Mechanical Engineering Congress and Exposition. Volume 3: Biomedical and Biotechnology Engineering. Tampa, Florida, USA. November 3–9, 2017. V003T04A024. ASME. https://doi.org/10.1115/IMECE2017-71442
Download citation file:
30
Views
Related Proceedings Papers
Related Articles
A Primary Computational Fluid Dynamics Study of Pre- and Post-TEVAR With Intentional Left Subclavian Artery Coverage in a Type B Aortic Dissection
J Biomech Eng (November,2019)
Influence of the Anatomical Structure on the Hemodynamics of Iliac Vein Stenosis
J Biomech Eng (January,2023)
Simulating Subject-Specific Aortic Hemodynamic Effects of Valvular Lesions in Rheumatic Heart Disease
J Biomech Eng (November,2023)
Related Chapters
Concluding remarks
Mechanical Blood Trauma in Circulatory-Assist Devices
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Impact of CCF Assumptions on PSA and PSA Application Calculations (PSAM-0172)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)