This study compares the effects of lingualized and linear occlusion schemes on the stress distribution of an implant retained mandibular overdenture (IRO) using finite element analysis (FEA). A high fidelity solid model of mandibular overdenture incorporating cusps and fossae of occlusal surface with two anterior implants in the canine regions and residual ridge support in the posterior region of the alveolar bone was modeled in SolidWorks and imported to ANSYS for stress analysis. The load was applied vertically to the central grooves and buccal cusp tips of the premolars and molar teeth for the lingualized and linear occlusion respectively. The loading magnitudes were 200 N on the premolars and 200 N on the molar teeth with multiple contact locations. The results show that the linear occlusion scheme generated higher stress in the implants and the prosthetic bar than the lingualized occlusion. The locations of high stress concentrations were the neck of the implants and the implant-prosthetic bar intersection for both the occlusion schemes. However, in the cortical bone lingualized occlusion loading scheme generated higher stress (max principal stress) than the linear one suggesting possibility of greater bone loss. The results of this study could be used to comprehend the stress distribution in the denture teeth, base, bone-implant interface and surrounding bone for the two occlusion concepts and may be of help to the clinicians in choosing the right scheme for the edentulous patients.
Skip Nav Destination
ASME 2015 International Mechanical Engineering Congress and Exposition
November 13–19, 2015
Houston, Texas, USA
Conference Sponsors:
- ASME
ISBN:
978-0-7918-5738-0
PROCEEDINGS PAPER
Effects of Lingualized and Linear Occlusion Schemes on the Stress Distribution of an Implant Retained Overdenture Using Finite Element Analysis Available to Purchase
Md Abu Hasan
Md Abu Hasan
University of Texas at Arlington, Arlington, TX
Search for other works by this author on:
Md Abu Hasan
University of Texas at Arlington, Arlington, TX
Paper No:
IMECE2015-52265, V003T03A049; 10 pages
Published Online:
March 7, 2016
Citation
Hasan, MA. "Effects of Lingualized and Linear Occlusion Schemes on the Stress Distribution of an Implant Retained Overdenture Using Finite Element Analysis." Proceedings of the ASME 2015 International Mechanical Engineering Congress and Exposition. Volume 3: Biomedical and Biotechnology Engineering. Houston, Texas, USA. November 13–19, 2015. V003T03A049. ASME. https://doi.org/10.1115/IMECE2015-52265
Download citation file:
18
Views
Related Proceedings Papers
Analysis of Finger PIP Implants
IMECE2003
Related Articles
In Vitro Fatigue Failure of Cemented Acetabular Replacements: A Hip Simulator Study
J Biomech Eng (April,2008)
A Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact
J Biomech Eng (June,2002)
Design of an Osseointegrated Lower Limb Prosthetic Force Limiting Connection
J. Med. Devices (June,2011)
Related Chapters
Subsection NB—Class 1 Components
Companion Guide to the ASME Boiler & Pressure Vessel Code, Volume 1, Second Edition
Stress Analysis of Gas Turbine Blade under Different Loads Using Finite Element Modeling
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
The Effect of Load Interaction and Sequence on the Fatigue Behavior of Notched Coupons
Cyclic Stress-Strain Behavior—Analysis, Experimentation, and Failure Prediction