Buildings are responsible for at least 40% of energy use in most countries of the world, and for up to 21% of greenhouse gas emissions globally. As this trend continues, real-time building load measurements are essential for dynamic load response control, understanding and improvement of load distributions and profiles, and for climate-responsive design, particularly in commercial buildings. The focus in this paper is the cooling load, which is the rate at which heat must be removed from the controlled zone to maintain the desired temperature. Estimation of maximum cooling load is necessary for sizing of cooling equipments. However, details needed for whole-building simulation are often unreliable or unavailable. As such, simplified models with reasonable accuracy and computational requirements are often used. A cyber-physical system, integration of physical sensors and mathematical model, is proposed in this paper for cooling load estimation. The physical sensor measurements are limited to outside air temperature, solar radiation, room air temperature, and building plug load. Meanwhile, resistance-capacitance (RC) concept was adopted to describe the physics and dynamics of the building envelope for its simplicity and reasonable computational requirements. The cyber-physical system was tested using a typical office having two thermal zones and compared with simulation results from EnergyPlus, a whole building simulation program. Phenomenon such as infiltration, inter-zone air mixing, and air moisture control were not taken into account for the model. Results are presented to determine the accuracy of the simplified model for cooling load estimation.
Skip Nav Destination
ASME 2013 International Mechanical Engineering Congress and Exposition
November 15–21, 2013
San Diego, California, USA
Conference Sponsors:
- ASME
ISBN:
978-0-7918-5640-6
PROCEEDINGS PAPER
Performance Analysis of a Simplified Model of Cooling Load for a Typical Office Building
Oluwaseyi T. Ogunsola,
Oluwaseyi T. Ogunsola
University of Oklahoma, Norman, OK
Search for other works by this author on:
Li Song
Li Song
University of Oklahoma, Norman, OK
Search for other works by this author on:
Oluwaseyi T. Ogunsola
University of Oklahoma, Norman, OK
Li Song
University of Oklahoma, Norman, OK
Paper No:
IMECE2013-64040, V011T06A025; 8 pages
Published Online:
April 2, 2014
Citation
Ogunsola, OT, & Song, L. "Performance Analysis of a Simplified Model of Cooling Load for a Typical Office Building." Proceedings of the ASME 2013 International Mechanical Engineering Congress and Exposition. Volume 11: Emerging Technologies. San Diego, California, USA. November 15–21, 2013. V011T06A025. ASME. https://doi.org/10.1115/IMECE2013-64040
Download citation file:
18
Views
Related Proceedings Papers
Related Articles
Insulated Glass Unit in High-Glazed Office Buildings in Brazil: Comparative HVAC Consumption Analyses
J. Eng. Sustain. Bldgs. Cities (May,2022)
Financial Viability of Energy Conservation Using Natural Light in an Academic Building in Temperate Zone
J. Sol. Energy Eng (December,2016)
On the Electrification of Winter Season in Cold Climate Megacities—The Case of New York City
J. Eng. Sustain. Bldgs. Cities (August,2023)
Related Chapters
Dynamic Cool Roofing Systems
Advanced Energy Efficient Building Envelope Systems
Microstructure Evolution and Physics-Based Modeling
Ultrasonic Welding of Lithium-Ion Batteries
An Energy Efficient Clustering Method for Wireless Sensor Networks
International Conference on Computer Engineering and Technology, 3rd (ICCET 2011)