The purpose of this study is to apply the computational fluid dynamics (CFD) technique to evaluate the tracheal airway pressure change before and after the vascular ring surgery (VRS) based on patient computed tomography (CT) images. Computer simulation results also show that after a surgical treatment the pressure drop in the tracheal airway was significantly decreased, especially for low inspiratory and expiratory velocities. In other words, the flow resistance in the tracheal airway becomes decreased after the VRS when the airway is expanded. The airway flow resistance of tracheal stenosis caused by CVR can be augmented by increased air flow velocity. Numerical results show that the pressure drop in the tracheal airway was 0.1099 Pa for the inlet inspiratory velocity of 10 cm/s before the VRS. After the VRS, the pressure drop was reduced and became 0.0598 Pa. In the meantime, the improvement gain was 45.58%. In word words, the pressure drop was reduced after the vascular ring surgery. Therefore, the CFD approach can be a useful method for quantifying the change of airway resistance and evaluating the effectiveness of relief of tracheal stenosis by the VRS.
Skip Nav Destination
ASME 2013 International Mechanical Engineering Congress and Exposition
November 15–21, 2013
San Diego, California, USA
Conference Sponsors:
- ASME
ISBN:
978-0-7918-5621-5
PROCEEDINGS PAPER
Computational Fluid Dynamics Analysis of Pressure Drop Alteration in the Trachea Before and After Vascular Ring Surgery
Tzu-Ching Shih,
Tzu-Ching Shih
China Medical University, Taichung City, Taiwan
Search for other works by this author on:
Tzyy-Leng Horng,
Tzyy-Leng Horng
Feng Chia University, Taichung City, Taiwan
Search for other works by this author on:
Fong-Lin Chen
Fong-Lin Chen
Chung Shang Medical University, Taichung City, Taiwan
Search for other works by this author on:
Tzu-Ching Shih
China Medical University, Taichung City, Taiwan
Tzyy-Leng Horng
Feng Chia University, Taichung City, Taiwan
Fong-Lin Chen
Chung Shang Medical University, Taichung City, Taiwan
Paper No:
IMECE2013-63933, V03AT03A034; 3 pages
Published Online:
April 2, 2014
Citation
Shih, T, Horng, T, & Chen, F. "Computational Fluid Dynamics Analysis of Pressure Drop Alteration in the Trachea Before and After Vascular Ring Surgery." Proceedings of the ASME 2013 International Mechanical Engineering Congress and Exposition. Volume 3A: Biomedical and Biotechnology Engineering. San Diego, California, USA. November 15–21, 2013. V03AT03A034. ASME. https://doi.org/10.1115/IMECE2013-63933
Download citation file:
8
Views
Related Proceedings Papers
Related Articles
FSI Analysis of a Human Trachea Before and After Prosthesis Implantation
J Biomech Eng (July,2011)
Contributions of Kinetic Energy and Viscous Dissipation to Airway Resistance in Pulmonary Inspiratory and Expiratory Airflows in Successive Symmetric Airway Models With Various Bifurcation Angles
J Biomech Eng (January,2018)
Pharyngeal Airflow Analysis in Obstructive Sleep Apnea Patients Pre- and Post-Maxillomandibular Advancement Surgery
J. Fluids Eng (September,2009)
Related Chapters
Introduction and scope
Impedimetric Biosensors for Medical Applications: Current Progress and Challenges
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)
Spherical SOFM: Implications for Forensics and Craniofacial Surgery
Intelligent Engineering Systems through Artificial Neural Networks