In this study, enhancement in forced convection inside a square channel by a two-stage electrohydrodynamic (EHD) gas pump has been examined by numerical simulations. The EHD gas pump with 28 emitting electrodes in each stage has been evaluated for a wide range of operating voltages starting from the corona threshold voltage up to 28 kV for further improvement in its performance over that of a single-stage. To achieve the maximum enhancement in heat transfer, the emitting electrodes of the corona wind generator are flush mounted on the channel walls so that the corona wind produced directly perturbs the boundary layer. The results show that EHD technique has a great potential for applications in thermal management.