Fresh water is one of the few resources which is scarce and has no replacement; it is also closely coupled to energy consumption. Fresh water usage for power generation and other cooling applications is well known and accounts for 40% of total freshwater withdrawal in the U. S[1]. A significant amount of energy is embedded in the consumption of water for conveyance, treatment and distribution of water. Waste water treatment plants also consume a significant amount of energy. For example, water distribution systems and water treatment plants consume 1.3MWh and 0.5MWh[2], respectively, for every million gallons of water processed. Water consumption in data centers is often overlooked due to low cost impact compared to energy and other consumables. With the current trend towards local onsite generation[3], the role of water in data centers is more crucial than ever. Apart from actual water consumption, the impact of embedded energy in water is only beginning to be considered in water end-use analyses conducted by major utilities[4]. From a data center end-use perspective, water usage can be characterized as direct, for cooling tower operation, and indirect, for power generation to operate the IT equipment and cooling infrastructure[5]. In the past, authors have proposed and implemented metrics to evaluate direct and indirect water usage using an energy-based metric. These metrics allow assessment of water consumption at various power consumption levels in the IT infrastructure and enable comparison with other energy efficiency metrics within a data center or among several data centers[6]. Water consumption in data centers is a function of power demand, outside air temperature and water quality. While power demand affects both direct and indirect water consumption, water quality and outside air conditions affect direct water consumption. Water from data center infrastructure is directly discharged in various forms such as water vapor and effluent from cooling towers. Classification of direct water consumption is one of the first steps towards optimization of water usage. Subsequently, data center processes can be managed to reduce water intake and discharge. In this paper, we analyze water consumption from data center cooling towers and propose techniques to reuse and reduce water in the data center.
Skip Nav Destination
ASME 2010 International Mechanical Engineering Congress and Exposition
November 12–18, 2010
Vancouver, British Columbia, Canada
Conference Sponsors:
- ASME
ISBN:
978-0-7918-4429-8
PROCEEDINGS PAPER
Water Utilization in Data Center Infrastructure
Ratnesh Sharma,
Ratnesh Sharma
Hewlett-Packard Laboratories, Palo Alto, CA
Search for other works by this author on:
Rocky Shih,
Rocky Shih
Hewlett-Packard Laboratories, Palo Alto, CA
Search for other works by this author on:
Alan McReynolds,
Alan McReynolds
Hewlett-Packard Laboratories, Palo Alto, CA
Search for other works by this author on:
Cullen Bash,
Cullen Bash
Hewlett-Packard Laboratories, Palo Alto, CA
Search for other works by this author on:
Chandrakant Patel,
Chandrakant Patel
Hewlett-Packard Laboratories, Palo Alto, CA
Search for other works by this author on:
Tom Christian
Tom Christian
Hewlett-Packard Laboratories, Fort Collins, CO
Search for other works by this author on:
Ratnesh Sharma
Hewlett-Packard Laboratories, Palo Alto, CA
Rocky Shih
Hewlett-Packard Laboratories, Palo Alto, CA
Alan McReynolds
Hewlett-Packard Laboratories, Palo Alto, CA
Cullen Bash
Hewlett-Packard Laboratories, Palo Alto, CA
Chandrakant Patel
Hewlett-Packard Laboratories, Palo Alto, CA
Tom Christian
Hewlett-Packard Laboratories, Fort Collins, CO
Paper No:
IMECE2010-40819, pp. 1413-1419; 7 pages
Published Online:
April 30, 2012
Citation
Sharma, R, Shih, R, McReynolds, A, Bash, C, Patel, C, & Christian, T. "Water Utilization in Data Center Infrastructure." Proceedings of the ASME 2010 International Mechanical Engineering Congress and Exposition. Volume 5: Energy Systems Analysis, Thermodynamics and Sustainability; NanoEngineering for Energy; Engineering to Address Climate Change, Parts A and B. Vancouver, British Columbia, Canada. November 12–18, 2010. pp. 1413-1419. ASME. https://doi.org/10.1115/IMECE2010-40819
Download citation file:
38
Views
Related Proceedings Papers
Related Articles
Analytical Modeling for Thermodynamic Characterization of Data Center Cooling Systems
J. Electron. Packag (June,2009)
Implementation of Energy Efficiency Strategies in Cooling Towers—A Techno-Economic Analysis
J. Energy Resour. Technol (January,2018)
Related Chapters
Makeup Water Treatment Plant Start-Up
Consensus on Pre-Commissioning Stages for Cogeneration and Combined Cycle Power Plants
Overview
Energy, Technology, and the Environment
The Context of Thermal Power Plant Water Usage
Thermal Power Plant Cooling: Context and Engineering