At present, climate change and rising energy prices motivate the researchers to focus on better utilization of energy for space cooling applications. The chilled beam system has already been widely used in Europe for better utilization of energy for space cooling. But, the condensation on the chilled ceiling panel limits its application in the hot and humid climates. Operating a chilled beam system for such warm and humid climate requires the integration of desiccant system, which needs to be regenerated thermally for the purpose of the indoor air quality control. This paper emphasis the performance analysis of a thermally regenerated desiccant system integrated with a building chilled beam system in Singapore. A TRNSYS simulation model of such system has been developed to investigate the thermal performance. In this model, the chilled beam system meets the sensible load of the cooling space, while the desiccant air handling system meets the latent load of the cooling space. To regenerate this desiccant system, different heat sources such as solar, electricity and waste heat are considered in the analysis. It has been found that this integrated desiccant system with active chilled beam meets the cooling load (space temperature 21°C to 25°C and relative humidity between 55% ∼ 65%) of an office building effectively. It has also been found that the utilization of solar energy as heat source for desiccant regeneration decreases the energy consumption of the system at about 20% and reduces the operating cooling cost at about 1.5 to 2.5 times than the conventional VAV system.
Skip Nav Destination
ASME 2010 International Mechanical Engineering Congress and Exposition
November 12–18, 2010
Vancouver, British Columbia, Canada
Conference Sponsors:
- ASME
ISBN:
978-0-7918-4429-8
PROCEEDINGS PAPER
Performance Analysis of Thermally Regenerated Desiccant System Integrated With Chilled Beam for Warm Humid Climate
M. A. Wahed,
M. A. Wahed
Nanyang Technological University, Singapore
Search for other works by this author on:
Y. W. Wong,
Y. W. Wong
Nanyang Technological University, Singapore
Search for other works by this author on:
K. C. Toh,
K. C. Toh
Nanyang Technological University, Singapore
Search for other works by this author on:
H. K. Ho
H. K. Ho
Nanyang Technological University, Singapore
Search for other works by this author on:
M. A. Wahed
Nanyang Technological University, Singapore
Y. W. Wong
Nanyang Technological University, Singapore
K. C. Toh
Nanyang Technological University, Singapore
H. K. Ho
Nanyang Technological University, Singapore
Paper No:
IMECE2010-40263, pp. 1375-1382; 8 pages
Published Online:
April 30, 2012
Citation
Wahed, MA, Wong, YW, Toh, KC, & Ho, HK. "Performance Analysis of Thermally Regenerated Desiccant System Integrated With Chilled Beam for Warm Humid Climate." Proceedings of the ASME 2010 International Mechanical Engineering Congress and Exposition. Volume 5: Energy Systems Analysis, Thermodynamics and Sustainability; NanoEngineering for Energy; Engineering to Address Climate Change, Parts A and B. Vancouver, British Columbia, Canada. November 12–18, 2010. pp. 1375-1382. ASME. https://doi.org/10.1115/IMECE2010-40263
Download citation file:
9
Views
Related Proceedings Papers
Related Articles
Analysis of a Solar Space Cooling System Using Liquid Desiccants
J. Energy Resour. Technol (December,1990)
A Liquid Desiccant System for Solar Cooling and Dehumidification
J. Sol. Energy Eng (August,2004)
The Effect of Plate Spacing on Free Convection Between Heated Parallel Plates
J. Heat Transfer (May,1992)
Related Chapters
Performance Prediction of Solar Absorption Cooling Systems Assisted by Gas Heaters
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Role of Wind Energy Technology in India and Neighboring Countries
Wind Energy Applications
Large Scale Solar Power, Hydrogen Developments, and Building Applications of Solar
Solar Energy Applications