Experimental and clinical evidence indicate that degree of arterial injury after stent implantation is strongly linked with various stent designs. In this study, Computational models are developed to predict stents-induced arterial strain and stress during the stenting procedure. The intramural stresse filed in the stenotic vessel wall is obtained to understand the injuries caused by stent implantation. Circumferential tensile stresses are maximal in the wall near the plaque edge, and the stress values are much higher than the tensile strength of the wall medial. Stress gradient at the interface among the stent, plaque and artery are also high. These results indicate a possibility of the injury near the edge of contact surface. The stress gradient and the vessel injury may be reduced by alternating stent designs.
Skip Nav Destination
ASME 2009 International Mechanical Engineering Congress and Exposition
November 13–19, 2009
Lake Buena Vista, Florida, USA
Conference Sponsors:
- ASME
ISBN:
978-0-7918-4375-8
PROCEEDINGS PAPER
The Stent Artery Interaction Available to Purchase
Linxia Gu,
Linxia Gu
University of Nebraska-Lincoln, Lincoln, NE
Search for other works by this author on:
Aswini K. Muttyam
Aswini K. Muttyam
C-Lock Technology Inc., Rapid City, SD
Search for other works by this author on:
Linxia Gu
University of Nebraska-Lincoln, Lincoln, NE
Aswini K. Muttyam
C-Lock Technology Inc., Rapid City, SD
Paper No:
IMECE2009-12389, pp. 413-416; 4 pages
Published Online:
July 8, 2010
Citation
Gu, L, & Muttyam, AK. "The Stent Artery Interaction." Proceedings of the ASME 2009 International Mechanical Engineering Congress and Exposition. Volume 2: Biomedical and Biotechnology Engineering. Lake Buena Vista, Florida, USA. November 13–19, 2009. pp. 413-416. ASME. https://doi.org/10.1115/IMECE2009-12389
Download citation file:
10
Views
Related Proceedings Papers
Related Articles
Tension and Combined Tension-Extension Structural Response and Tolerance Properties of the Human Male Ligamentous Cervical Spine
J Biomech Eng (August,2009)
Computational Examination of the Effect of Material Inhomogeneity on the Necking of Stent Struts Under Tensile Loading
J. Appl. Mech (September,2007)
Hydrodynamic Effects of Compliance Mismatch in Stented Arteries
J Biomech Eng (February,2011)
Related Chapters
Section III: Subsections NC and ND — Class 2 and 3 Components
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Fourth Edition
Basic Concepts
Design & Analysis of ASME Boiler and Pressure Vessel Components in the Creep Range
Section VIII: Division 2–Alternative Rules
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 2, Sixth Edition