Mechanical changes in breast tissues as a result of cancer are usually detected through palpation by the physician and/or self examination. However, physicians are unable to palpate most masses under 1 cm in diameter and microscopic diseases. The goal of our study is to introduce the application of the Harmonic Motion Imaging (HMI), an acoustic radiation force technique, for reliable sensitive tumor detection and real-time monitoring of tumor ablation. Here, we applied the HMI technique using a single-element Focused Ultrasound (FUS) transducer. Due to the highly localized and harmonic nature of the response, the motion characteristics can be directly linked to the regional tissue modulus. In this experiment, a confocal transducer, combining a 4.68 MHz therapy (FUS) and a 7.5 MHz diagnostic (pulse-echo) probe, was used. The FUS beam was further modulated by a low AM continuous wave at 25 Hz. A pulser/receiver was used to drive the pulse-echo transducer at a Pulse Repetition Frequency (PRF) of 5.4 kHz. The radio-frequency (RF) signals were acquired using a standard pulse echo technique. The intensity amplitudes of the FUS beam at the focus (Ispta) were 231 W/cm2 for tumor detection and 1086 W/cm2 for FUS ablation. An analog bandpass filter was used to remove the spectrum of the FUS beam prior to displacement estimation. The resulting axial tissue displacement (i.e., HMI displacement) was estimated using an RF-based speckle tracking technique based on 1D cross-correlation. For tumor mapping, a harmonic radiation force was applied using a 2D raster-scan technique. The 3D HMI image was obtained by combining multiple 2D planes at different depths. The 2D and 3D HMI images in ex vivo breast tissues could detect a benign tumor (2×5×5mm3) surrounded by normal tissue, and a malignant tumor (8×7×5mm3) embedded in glandular and fat tissues. For FUS therapy, temperature measurements and RF signals were acquired during thermal ablation. HMI images during FUS ablation showed lower displacements, indicating thus tissue hardening due to lesion formation at temperatures higher than 50°C. A finite-element model (FEM) simulation was also used to analyze the findings of the experimental results. In conclusion, this technique demonstrates feasibility of the HMI technique for tumor detection and characterization, as well as real-time monitoring of tissue ablation based on the associated tissue elasticity changes.
Skip Nav Destination
ASME 2007 International Mechanical Engineering Congress and Exposition
November 11–15, 2007
Seattle, Washington, USA
Conference Sponsors:
- ASME
ISBN:
0-7918-4296-7
PROCEEDINGS PAPER
Mapping of Regional Cancerous Tissue Mechanical Property Changes Using Harmonic Motion Imaging
Caroline Maleke,
Caroline Maleke
Columbia University, New York, NY
Search for other works by this author on:
Jianwen Luo,
Jianwen Luo
Columbia University, New York, NY
Search for other works by this author on:
Assimina A. Pelegri,
Assimina A. Pelegri
Rutgers State University, Piscataway, NJ
Search for other works by this author on:
Elisa E. Konofagou
Elisa E. Konofagou
Columbia University, New York, NY
Search for other works by this author on:
Caroline Maleke
Columbia University, New York, NY
Jianwen Luo
Columbia University, New York, NY
Assimina A. Pelegri
Rutgers State University, Piscataway, NJ
Elisa E. Konofagou
Columbia University, New York, NY
Paper No:
IMECE2007-42294, pp. 127-133; 7 pages
Published Online:
May 22, 2009
Citation
Maleke, C, Luo, J, Pelegri, AA, & Konofagou, EE. "Mapping of Regional Cancerous Tissue Mechanical Property Changes Using Harmonic Motion Imaging." Proceedings of the ASME 2007 International Mechanical Engineering Congress and Exposition. Volume 2: Biomedical and Biotechnology Engineering. Seattle, Washington, USA. November 11–15, 2007. pp. 127-133. ASME. https://doi.org/10.1115/IMECE2007-42294
Download citation file:
11
Views
Related Proceedings Papers
Related Articles
Thermal Assessment of Ablation Limit of Subsurface Tumor During Focused Ultrasound and Laser Heating
J. Thermal Sci. Eng. Appl (March,2016)
Focused Ultrasound Ablation for the Treatment of Patients With Localized Deformed Breast Cancer: Computer Simulation
J. Heat Transfer (October,2019)
Pulsed Ultrasound Assisted Thermo-Therapy for Subsurface Tumor Ablation: A Numerical Investigation
J. Thermal Sci. Eng. Appl (August,2021)
Related Chapters
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
Experimental Studies
Nanoparticles and Brain Tumor Treatment
Introduction
Nanoparticles and Brain Tumor Treatment