New architectural concepts and features are designed to give green or sustainable buildings for having a better environment in the future. These new concepts and features, especially those with glass facades, might have difficulties in complying with the fire safety codes, especially in those countries with only prescriptive codes. Performance-based design has to be applied. However, engineering performance-based fire codes are still under development and even the performance-based concept has not yet been accepted in some cities such as Hong Kong. There is fire safety concern in buildings with natural ventilation provision driven by wind action. In this paper, Computational Fluid Dynamics (CFD) will be applied to study natural ventilation in a small flat under wind action. Indoor air flow for a flat in a typical building will be simulated for windows at different locations. Mixing of heat due to a fire inside the building will be studied. The CFD tool selected is PHOENICS.

1.
Chow
W. K.
,
2003
, “
Fire Safety in Green or Sustainable Buildings: Application of the Fire Engineering Approach in Hong Kong
,”
Arch. Sci. Rev.
,
46
(
3)
, pp.
297
303
.
2.
Chow, W. K., 2003, “Wind Environment for a High-Rise Building Adjacent to a Vertical Wall,” Keynote speech presented at the International Conference on Sustainable Development in Building and Environment, SET2 (Sustainable Energy Technology), held on 24-27 October 2003, Chongqing, China and appeared also in J. Chongqing University (English Edition), Special Issue, October, 2, pp. 19–25.
3.
Chow
W. K.
,
2004
, “
Wind-Induced Indoor-Air Flow in a High-Rise Building Adjacent to a Vertical Wall
,”
Appl. Energy
,
77
(
2)
, pp.
225
234
.
4.
Hanzawa
H.
,
Melikov
A. K.
, and
Fanger
P. O.
,
1987
, “
Airflow Characteristics in the Occupied Zone of Ventilated Spaces
,”
ASHRAE Trans.
,
93
(
1)
, pp.
524
539
.
5.
Chow
W. K.
,
2001
, “
On Managing Indoor Air Quality in Hong Kong
,”
J. Env. Sys.
,
28
(
4)
, pp.
271
277
.
6.
Buildings Department, 1999, Review of Lighting and Ventilation Requirements in Buildings, Consultancy Agreement Brief, Buildings Department, Hong Kong Special Administrative Region, China.
7.
Chow
W. K.
,
2000
, “
A Comment on Studying the Ventilation Requirements for Buildings in the Hong Kong Special Administrative Region
,”
Intl. J. Arch. Sci.
,
1
(
1)
, pp.
1
13
.
8.
Emmerich, S. J., 1997, Use of Computational Fluid Dynamics to Analyze Indoor Air Quality Issues, Report NISTIR 5997, Building and Fire Research Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland, USA.
9.
Concentration, Heat and Mass Ltd., 1998, Starting PHOENICS-VR version 3.1, Report TR324, London, UK.
10.
Yang
K. T.
,
Lloyd
J. R.
and
Kanury
A. M.
,
1984
, “
Modeling of Turbulent Buoyant Flows in Aircraft Cabins
,”
Combustion Science Technology
,
39
, pp.
107
118
.
11.
Chow, W. K., and Gao, Y., 2006, “Wall Functions at the Upwind Shape Convex Corners in Simulating Incident Air Flow on a Cube,” The Fourth International Symposium on Computational Wind Engineering (CWE 2006), Pacifico Yokohama, Yokohama, Japan, July 16-19, 2006 — Paper presented.
12.
Chow, W. K., 2005, “Atrium Smoke Exhaust and Technical Issues on Hot Smoke Tests,” ASME 2005 Summer Heat Transfer Conference, July 17-22, 2005, Westin St. Francis, San Francisco, CA, USA, Paper HT2005–72412, 4 pages.
13.
Zeng
W. R.
,
Li
S. F.
, and
Chow
W. K.
,
2002
, “
Review on Chemical Reactions of Burning Poly(methyl methacrylate) PMMA
,”
Journal of Fire Sciences
,
20
(
5)
, pp.
401
433
14.
Etheridge, D., and Sandberg, M., 1996, Building Ventilation: Theory and Measurement, John Wiley & Sons, Chichester, UK.
15.
Arnold, D., 1997, “Natural Ventilation in a Large Mixed Mode Building,” Naturally Ventilated Buildings: Buildings for the senses, the economy and society, Edited by D. Clements-Croome, E & FN Spon, London, UK, Chap. 10.
This content is only available via PDF.
You do not currently have access to this content.