This paper describes the design of an above-knee prosthesis with actively powered knee and ankle joints, both of which are actuated via pneumatic actuators. The prosthesis serves as a laboratory test-bed to validate the design and develop of control interfaces for future self-contained versions (i.e., with onboard hot-gas power and computing), and therefore includes a tether for both pneumatic power and control. The prototype prosthesis provides the full range of motion for both the knee and ankle joints while providing 100% of the knee torque required for fast cadence walking and stair climbing and 76% and 100%, respectively, of the ankle torque required for fast cadence walking and for stair climbing, based on the torques required by a healthy 75 kg subject. The device includes sensors to measure knee and ankle torque and position, in addition to a load cell that measures the interaction force and (sagittal and frontal planes) moments between the user and device.

1.
Winter, D.A. (1991) The biomechanics and motor control of human gait: normal, elderly and pathological, University of Waterloo Press, 2nd ed.
2.
Winter
D. A.
and
Sienko
S. E.
(
1988
)
Biomechanics of below-knee amputee gait
.
J. Biomechanics
.
21
,
361
367
.
3.
Nadeau
S.
,
McFadyen
B. J.
, and
Malouin
F.
(
2003
)
Frontal and sagittal plane analyses of the stair climbing task in healthy adults aged over 40 years: What are the challenges compared to level walking?
Clinical Biomechanics
, vol.
18
, no.
10
, pp.
950
959
4.
Riener
R.
,
Rabuffetti
M.
, and
Frigo
C.
(
1999
)
Joint powers in stair climbing at different slopes
.
Proceedings of the IEEE International Conference on Engineering in Medicine and Biology
, vol.
1
, p.
530
530
.
5.
Prilutsky
B. I.
,
Petrova
L. N.
, and
Raitsin
L. M.
(
1996
)
Comparison of mechanical energy expenditure of joint moments and muscle forces during human locomotion
.
Journal of Biomechanics
, vol.
29
, no.
4
, pp.
405
415
.
6.
DeVita
P.
,
Torry
M.
,
Glover
K. L.
, and
Speroni
D. L.
A Functional Knee Brace Alters Joint Torque and Power Patterns during Walking and Running
,
Journal of Biomechanics
, vol.
29
, no.
5
, pp.
583
588
,
1996
.
7.
Nagano
A.
,
Ishige
Y.
, and
Fukashiro
S.
(
1998
)
Comparison of new approaches to estimate mechanical output of individual joints in vertical jumps
.
Journal of Biomechanics
, vol.
31
, no.
10
, pp.
951
955
.
8.
Jacobs
R.
,
Bobbert
M. F.
,
van Ingen Schenau
G. J.
(
1996
)
Mechanical output from individual muscles during explosive leg extensions: the role of biarticular muscles
.
Journal of Biomechanics
, vol.
29
, no.
4
, pp.
513
523
.
9.
Waters
R.
,
Perry
J.
,
Antonelli
D.
, and
Hislop
H.
(
1976
)
Energy cost of walking amputees: the influence of level of amputation
.
J. Bone and Joint Surgery
.
58A
,
42
46
.
10.
Flowers, W.C., (1973) A Man-Interactive Simulator System for Above-Knee Prosthetics Studies, Department of Mechanical Engineering PhD Thesis, MIT.
11.
Donath, M., (1974) Proportional EMG Control for Above- Knee Prosthesis’, Department of Mechanical Engineering Masters Thesis, MIT.
12.
Grimes, D. L. (1979) An Active Multi-Mode Above Knee Prosthesis Controller. Department of Mechanical Engineering PhD Thesis, MIT.
13.
Grimes
D. L.
,
Flowers
W. C.
, and
Donath
M.
(
1977
)
Feasibility of an active control scheme for above knee prostheses
.
ASME Journal of Biomechanical Engineering
, vol.
99
, no.
4
, pp.
215
221
.
14.
Stein, J.L. (1983). Design Issues in the Stance Phase Control of Above-Knee Prostheses. Department of Mechanical Engineering PhD Thesis, MIT.
15.
Stein
J. L.
, and
Flowers
W. C.
(
1987
)
Stance phase control of above-knee prostheses: knee control versus SACH foot design
.
Journal of Biomechanics
, vol.
20
, no.
1
, pp.
19
28
.
16.
Flowers
W. C.
, and
Mann
R. W.
(
1977
)
Electrohydraulic knee-torque controller for a prosthesis simulator
.
ASME Journal of Biomechanical Engineering
, vol.
99
, no.
4
, pp.
3
8
.
17.
Popovic, D. and Schwirtlich, L. (1988) Belgrade active A/K prosthesis, in de Vries, J. (Ed.), Electrophysiological Kinesiology, Interm. Congress Ser. No. 804, Excerpta Medica, Amsterdam, The Netherlands, pp. 337–343.
18.
Klute, G.K., Czerniecki, J., Hannaford, B., (1998) Development of Powered Prosthetic Lower Limb, Proceedings of the First National Meeting, Veterans Affairs Rehabilitation Research and Development Service.
19.
Klute, G.K., Czerniecki, J., Hannaford, B., (2000) Muscle-Like Pneumatic Actuators for Below-Knee Prostheses, Proceedings the Seventh International Conference on New Actuators, pp. 289–292.
20.
Goldfarb
M.
,
Barth
E. J.
,
Gogola
M. A.
and
Wehrmeyer
J. A.
(
2003
)
Design and Energetic Characterization of a Liquid-Propellant-Powered Actuator for Self-Powered Robots
.
IEEE/ASME Transactions on Mechatronics
, vol.
8
, no.
2
, pp.
254
262
.
21.
Shields, B., and Goldfarb, M., (2005) Design and Energetic Characterization of a Solenoid Injected Liquid Monopropellant Powered Actuator for Self-Powered Robots, accepted for the 2005 IEEE International Conference on Robotics and Automation.
22.
Shields, B., Fite, K., and Goldfarb, M. (2004) Control of a Direct Injection Liquid Fueled Actuator, Proceedings of the ASME International Mechanical Engineering Congress and Exposition, IMECE2004-59442.
23.
Fite, K.B., Mitchell, J., Barth, E.J., and Goldfarb, M. (2004) Sliding Mode Control of a Direct-Injection Monopropellant-Powered Arm, American Control Conference, pp. 4461–4466.
24.
Gordon, CC, B. Bradtmiller, T. Churchill, C.E. Clauser, J.T. McConville, I. Tebbetts and R. Walker. 1988 Anthropometric Survey of US Army Personnel: Methods and Summary Statistics. Technical Report NATICK/TR-89/044, U.S. Army Natick Research, Development and Engineering Center, Natick, MA, 1989.
25.
Clauser CE, McConville JT, Young JM (1969) Weight, volume and center of mass of segments of the human body. AMRL-TR-69-70, Wright Patterson Airforce Base, Dayton, Ohio.
This content is only available via PDF.