This paper presents development of a BioMEMS device to mechanically stimulate single adherent cells by means of electrostatic actuation. The main components of the proposed device include a platform for cell placement and an electrostatic comb drive actuator to provide in-plane motion. A high frequency actuation method was used to enable actuation in aqueous solutions. Displacements greater than 5μm were measured when the device was actuated with a 1 MHz square wave signal with 10V peak amplitude in DI water. Additionally, this device was successfully actuated in ionic solutions up to 50mM NaCl aqueous solution using frequencies greater than 30 MHz. Significant electrolysis and corrosion of the polysilicon and metal layers was observed when the devices were actuated in saline solutions with peak voltages greater than 15V, thus indicating that there is a limit on the maximum actuation voltage that can be used. No noticeable actuation was observed in phosphate buffer solution (PBS) or cell culture medium even when frequencies as high as 50 MHz were used due to ion migration. Theoretical calculations suggest that frequencies of the order of 100-500 MHz will be required for actuation in cell culture media. Currently we are in the process of building an experimental set-up to allow use of such high frequencies. Initial results for cell plating experiments on the cell stretcher platform and other considerations for device implementation are discussed in the end.

1.
Bao
G.
,
Suresh
S.
,
2003
, “
Cell and molecular mechanics of biological materials
,”
Nature Materials
,
2
, pp.
715
725
.
2.
Zhu
C.
,
Bao
G.
, and
Wang
N.
,
2000
, “
CELLMECHANICS: Mechanical response, cell adhesion, and molecular Deformation
,”
Annu. Rev. Biomed. Eng.
,
2
, pp.
189
226
.
3.
Sheetz
M. P.
,
2001
, “
Cell control by membrane-cytoskeleton adhesion
,”
Nature reviews - molecular cell biology
,
2
, pp.
392
396
.
4.
Hamill
O. P.
, and
Martinac
B.
,
2001
, “
Molecular basis of mechanotransduction in living cells
,”
Physiological reviews
,
81
(
2
), pp.
685
740
.
5.
Brown
T. D.
,
2000
, “
Techniques for mechanical stimulation of cells in vitro: a review
,”
Journal of Biomechanics
,
33
, pp.
3
14
.
6.
Guck
J.
,
Ananthakrishnan
R.
,
Mahmood
H.
,
Moon
T. J.
,
Cunningham
C. C.
, and
Ka¨s
J.
, 2001, “
The optical stretcher: A novel laser tool to micromanipulate cells
,”
Biophysical Journal
,
81
(
2
), pp.
767
784
.
7.
Charras
G. T.
, and
Horton
M. A.
,
2002
, “
Single cell mechanotransduction and modulation analyzed by atomic force microscope indentation
,”
Biophysical Journal
,
8
(
6
), pp.
2970
2981
.
8.
Haque
M. A.
, and
Saif
M. T. A.
,
2001
, “
Microscale Materials Testing Using MEMS Actuators
,”
Journal of Microelectromechanical Systems
,
10
(
1
), pp.
146
152
.
9.
David B Serrell, Tammy Orsekovic, Dudley S Finch, and Roop Mahajan, 2005, “Design and Fabrication of a Uni-Axial BioMEMS Device for Quantifying Single-Cell Mechaninical Properites In Vitro,” Submitted to NIST Journal of Research, August 2005.
10.
Yang, S. and Saif, T., “Micromachined Force Sensors for the Study of Cell Mechanics,” Review of Scientific Instruments (in press).
11.
Koester, D., Cowen, A., Mahadevan, R., Stonefield, M., Hardy, B., 2003, “PolyMUMPs Design Handbook,” Revision 10.0, MEMSCAP.
12.
Jaecklin
V. P.
,
Linder
C.
,
Rooij
N. F. de
, and
Moret
J. M.
,
1992
, “
Micromechanical comb actuators with low driving voltage
,”
Journal of Micromechanics and Microengineering
,
2
(
4
), p.
250
255
.
13.
Green
N. G.
,
Ramos
A.
,
Gonza´lez
A.
,
Morgan
H.
, and
Castellanos
A.
,
2002
, “
Fluid flowby nonuniform ac electric fields in electrolytes on microelectrodes. III. Observation of streamlines and numerical simulation
,”
Phys. Rev. E
,
66
, pp.
026
-
305
.
14.
Jones
T. B.
,
Fowler
J. D.
,
Chang
Y. S.
,
Kim
C.-J.
,
2003
, “
Frequency-Based Relationship of Electrowetting and Dielectrophoretic Liquid Microactuation
,”
Langmuir
,
19
,
7646
7651
.
15.
Sameoto
D.
,
Hubbard
T.
,
Kujath
M.
,
2004
, “
Operation of electrothermal and electrostatic MUMPs microactuators underwater
,”
J. Micromech. Microeng.
,
14
, pp.
1359
1366
.
16.
Sounart
T. L.
,
Michalske
T. A.
, and
Zavadil
K. R.
,
2005
, “
Frequency-Dependent Electrostatic Actuation in Microfluidic MEMS
,”
Journal of MicroElectroMechanical Systems
,
14
(
1
), pp.
125
133
.
17.
Zavadil, K. R., Rising, M. A., and Galambos, P. C., 2002, “Limits of electrochemical processes at Si electrodes used at high field for aqueous microfluidic MEMS applications,” Proc. Electrochemical Society Microfabricated Systems and MEMS VI, Series PV2002-6, Pennington, NJ, pp. 144–152.
18.
Shea
H. R.
.
Gasparyan
A.
,
Chan
H. B.
,
Arney
S.
,
Frahm
R. E.
,
Lo´pez
D.
,
Jin
S.
, and
McConnell
R. P.
,
2004
, “
Effects of Electrical Leakage Currents on MEMS Reliability and Performance
,”
IEEE Transactions on Device and Materials Reliability
,
4
(
2
), pp.
198
207
.
19.
Hoivic
N. D.
,
Elam
J. W.
,
Linderman
R. J.
,
Bright
V. M.
,
George
S. M.
,
Lee
Y. C.
,
2003
, “
Atomic layer deposited protective coatings for micro-electromechanical systems
,”
Sensors and Actuators: A, Physical
,
103
, pp.
100
108
.
This content is only available via PDF.