Peripheral nerve regeneration conduits available today are single lumen conduits. Multi-lumen conduits offer advantages over currently available conduits in that multiple lumen better mimic the natural structure of the nerve, provide a greater surface area for neurite extension, and allow for more precisely located growth factors or support cells within the scaffold. This work describes and demonstrates the use of the stereolithography (SL) rapid prototyping technique for fabricating multi-lumen nerve guidance conduits (NGCs) out of photopolymerizable poly(ethylene glycol) (PEG). NGCs were fabricated from PEG-dimethacrylate (PEG-dma) molecular weight 1000 with 30% (w/v) aqueous solution and 0.5% (w/v) of the photoinitiator Irgacure 2959. The selection of the PEG-dma and photoinitiator concentration was based on previous work [13]. A 3D Systems 250/50 SL machine with a 250 μm laser beam diameter was used for the experiments in a slightly modified process where the NGCs were fabricated on a glass slide within a small flat-bottom cylindrical container placed on top of the SL machine’s original build platform. SL successfully manufactured three-dimensional, multi-layered and multi-material NGCs with varying overall NGC lengths and lumen sizes. Minimum lumen size, spacing, and geometric accuracy were constrained by the laser beam diameter and path, curing characteristics of the polymer solution, and UV transmission properties of the polymer solution and cured PEG-dma. Overall lengths of the NGCs were constrained by the ability of the conduit to self-support its own construction. Multiple material conduits were demonstrated by varying the build solution during the layering process. In summary, SL shows promise for fabrication of bioactive NGCs using PEG hydrogels, and the use of SL in this application offers the additional advantage of easily scaling up for mass production.

1.
Borkenhagen
M.
and
Aebischer
P.
,
1996
, “
Tissue-Engineering Approaches for Central and Peripheral Nervous-System Regeneration
,”
MRS Bulletin
,
21
(
11
), pp.
59
61
.
2.
Rodrigues de Oliveira
A. L.
,
Pierucci
A.
, and
de Brito Pereira
K.
,
2004
, “
Peripheral Nerve Regeneration through the Nerve Tubulization Technique
,”
Brazilian Journal of Morphological Sciences
,
21
(
4
), pp.
225
231
.
3.
Lundborg
G.
,
Rose´n
B.
,
Dahlin
L.
,
Holmbergm
J.
, and
Rose´n
I.
,
2004
, “
Tubular Repair of the Median or Ulnar Nerve in the Human Forearm: a 5-year Follow-up
,”
Journal of Hand Surgery (British and European Volume)
,
29B
(
2
), pp.
100
107
.
4.
Sundback
C.
,
Hadlock
T.
,
Cheney
M.
,
Vacanti
J.
,
2003
, “
Manufacture of Porous Polymer Nerve Conduits by a Novel Low-Pressure Injection Molding Process
,”
Biomaterials
,
24
, pp.
819
830
.
5.
Hadlock
T.
,
Sundback
C.
,
Hunter
D.
,
Cheney
M.
,
Vacanti
J. P.
,
2000
, “
A Polymer Foam Conduit Seeded with Schwann Cells Promotes Guided Peripheral Nerve Regeneration
,”
Tissue Engineering
,
6
(
2
), pp.
119
127
.
6.
Pallante, A., Arcaute, K., Medina, F., Wicker, R.B. and Mann, B.K., 2005, “Development of Multi-Lumen PEG Hydrogel Conduits,” 2005 Annual Meeting and Exposition of the Society for Biomaterials, Memphis, Tennessee, April 27–30, 2005 (abstract only).
7.
Comeau
B. M.
,
Umar
Y.
,
Gonsalves
K. E.
, and
Henderson
C. L.
,
2005
, “
New Materials and Methods for Hierarchically Structured Tissue Scaffolds
,”
Materials Research Society Symposium Proceedings
,
845
(
A
), pp.
1
6
.
8.
Cooke
M. N.
,
Fisher
J. P.
,
Dean
D.
,
Rimnac
C.
, and
Mikos
A. G.
,
2002
, “
Use of Stereolithography to Manufacture Critical-Sized 3D Biodegradable Scaffolds for Bone Ingrowth
,”
Journal of Biomedical Materials Research Part B: Applied Biomaterials
,
64B
, pp.
65
69
.
9.
Dhariwala
B.
,
Hunt
E.
, and
Boland
T.
,
2004
, “
Rapid Prototyping of Tissue-Engineering Constructs, Using Photopolymerizable Hydrogels and Sterolithography
,”
Tissue Engineering
,
10
(
9/10
), pp.
1316
1322
.
10.
Harris, J.M. & Zalipsky, S., 1997, “Poly(ethylene glycol): Chemistry and Biological Applications,” American Chemical Society Symposium Series 680.
11.
Mann
B. K.
,
Schmedlen
R. H.
,
West
J. L.
,
2001
, “
Tethered-TGF-β Increases Extracellular Matrix Production of Vascular Smooth Muscle Cells in Peptide-Modified Scaffolds
,”
Biomaterials
,
22
, pp.
439
44
.
12.
Mann
B. K.
,
Gobin
A. S.
,
Tsai
A. T.
,
Schmedlen
R. H.
,
West
J. L.
,
2001
, “
Smooth Muscle Cell Growth in Photopolymerized Hydrogels with Cell Adhesive and Proteolytically Degradable domains: Synthetic ECM Analogs for Tissue Engineering
,”
Biomaterials
,
22
, pp.
3045
51
.
13.
Arcaute
K.
,
Ochoa
L.
,
Medina
F.
,
Elkins
C.
,
Mann
B.
,
Wicker
R.
,
2005
a, “
Three-Dimensional PEG Hydrogel Construct Fabrication using Stereolithography
,”
Materials Research Society Symposium Proceedings
,
874
(
L
),
1
7
.
14.
Wicker, R.B., Medina, F., and Elkins, C.J., “Multi Material Micro-Fabrication: Extending Stereolithography to Tissue Engineering and Other Novel Applications,” 15th Annual Solid Freeform Fabrication Symposium, University of Texas at Austin, August 2–4, 2004, pp. 754–764.
15.
Wicker, R.B., Ranade, A., Medina, F., and Palmer, J., “Practical Considerations for Micro-Stereolithography of Embedded Micro-Channels,” SME Technical Paper TP04PUB210 (Dearborn, Michigan.: Society of Manufacturing Engineers, 2004).
16.
Arcaute, K., Ochoa, Mann, B., Wicker, R., 2005b, “Hydrogels in Stereolithography,” Proceedings of the 16th Annual Solid Freeform Fabrication Symposium, University of Texas at Austin, August 1–3.
This content is only available via PDF.
You do not currently have access to this content.