This study considers airflow simulations to evaluate the impact of different window air-conditioner locations on the thermal comfort in an office rooms (OR). This paper compares the air distribution for an office room by using computational fluid dynamics (CFD) modeling. The air distribution was modeled for a typical office room window air conditioning unit, air supply from a high pressure on the top and the low pressure exhaust on the bottom considering the existing manufacturing ratios for surface areas. Calculations were done for steady-state conditions including an occupant and a light source. The discharge angle for the supply grill of the AC unit was varied from 20 to 40 degrees. The position of the air conditioner was also varied and studied at 60%, 75% and 90% of the total height of the room. In addition the location of the occupant within the office room was varied. Predictions of the air movement, room temperature, room relative humidity, comfort level, and distribution of contaminants within the office room are shown. Analysis of these simulations is discussed. The positions of the air-conditioner unit, the inlet angle and the occupant position in the office room have shown to have important impacts on air quality and thermal comfort. Results are in good agreement with available experimental data.

1.
Sauer H, J., Howell R.H. and Coad W.J. 2001, “Principles of heating ventilating and air conditioning.” ASHRAE, Atlanta, Ga.
2.
Energy-efficient air aonditioning US Department of Energy http://www.eere.energy.gov/consumerinfo/factsheets/aircond.html
3.
Chow
W. F.
, and
Fung
W. F.
,
1996
, “
Numerical studies on indoor air flow in occupied zone of ventilated and air-conditioned space
,”
Building and Environment
,
31
, pp.
319
344
4.
Emmerich S.J., 1997, “Use of computational fluid dynamics to analyze indoor air quality issues,” NISTIR 5997, Building and Fire Research Laboratory, National Institute of Standards of Technology, Gaithersburg, MD.
5.
Gadgil A.J., Finlayson E.U., Hong K.H., and Sextro R.G., 1999, “Commercial CFD software capabilities for modeling a pulse release of pollutant in a large indoor space,” Proceeding of Indoor Air ’99, Edingburg, 4, pp. 749.
6.
Hirnikel
D. J.
,
Lipowicz
P. J.
, and
Law
R. W.
,
2002
, “
Predicting contaminant removal effectiveness of three air distribution systems by CFD modeling
,”
ASHRAE Transactions
,
108
(
1
), pp.
350
359
7.
H.C Hsu, H, Chiang, Y.C. Shih and R.J Shyu., 2000, “Implementation of displacement ventilation system by using wall-mounted air conditioning,” Air Distribution in Rooms, Roomvent 2000. Elsevier Science Ltd.
8.
Y.C. Shih, H, Chiang, and R.J Shyu., 2000, “The impact of the “Coanda Effect” on indoor air motion generated by a window-type air-conditioner,” Air Distribution in Rooms, Roomvent 2000. Elsevier Science Ltd.
9.
Ho, S.H., 2004, “Numerical simulation of thermal comfort and contaminant transport,” M.S. Thesis, University of South Florida, Tampa, Florida.
10.
Fountain, M., and C. Huizenga, 1995, “A thermal sensation model for use by the engineering profession. “ASHRAE Project 781-PR Final report. Atlanta, Ga.
11.
Yanzheng G., Jones B. W., Hosni M.H., and Gielda T.P., 2003, “Literature Review of the Advances in Thermal Comfort Modeling,” ASHRAE Transactions. Atlanta, Ga.
12.
ASHRAE, 1997, “Handbook of fundamentals,” American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc., Atlanta, Georgia
13.
Fanger P.O., 1970, “Thermal comfort analysis and applications in environmental engineering,” McGraw-Hill, New York
14.
Rohles
F. H.
and
Nevins
R. G.
,
1971
, “
The Nature of Thermal Comfort for Sedentary Man
,
ASHRAE Transactions
,
77
(
1
), pp.
239
244
15.
ANSI/ASHRAE Standard 55, 1992, Thermal Environment conditions for Human Occupancy. American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc., Atlanta, Georgia.
This content is only available via PDF.
You do not currently have access to this content.