Heat pump water heaters can cut electricity consumption, comparing with the conventional electric resistant water heating tanks by half. A conventional heat pump water heater (HPWH) requires a water circulating pump to sample water temperature every 15 minutes in the tank and to draw water to a condenser-water heat exchanger outside the tank, if water temperature is below the set point. The pump would be on at least once every 15 minutes, 24 hours a day. The novel design presented in this study was to insert the condenser coil through the opening on the top of the water tank. This design eliminated the need of the water circulating pumps, and thus greatly improved the reliability of the HPWH systems. Two types of condenser coil designs were considered; one was a bayonet tube (tube-in-tube) and one was the “U” tube. Previous test data indicated that “U” tube design performed better than the bayonet tube condenser coil, and thus only “U” tube condenser coil was considered in the study. With straight “U” tubes inserted into the tank, it was found that the convective heat transfer was not strong enough to break water temperature stratification in the tank, which resulted in a temperature differential of 16°C (30°F) from top to bottom. However, when the coil was built in “L” shape, the water stratification disappeared. A computational fluid dynamics code, CFD, was used to study the straight and L shaped condenser coils. Results from CFD simulation were compared with the experimental data and found they were close to each other.
Skip Nav Destination
ASME 2003 International Mechanical Engineering Congress and Exposition
November 15–21, 2003
Washington, DC, USA
Conference Sponsors:
- Advanced Energy Systems Division
ISBN:
0-7918-3708-4
PROCEEDINGS PAPER
CFD Solution and Experimental Testing of Buoyancy-Driven Convection Caused by Condensers Immersed in a Water Tank of HPWH
Zhiming Gao,
Zhiming Gao
Oak Ridge National Laboratory, Oak Ridge, TN
Search for other works by this author on:
Viung C. Mei,
Viung C. Mei
Oak Ridge National Laboratory, Oak Ridge, TN
Search for other works by this author on:
Fang C. Chen
Fang C. Chen
Oak Ridge National Laboratory, Oak Ridge, TN
Search for other works by this author on:
Zhiming Gao
Oak Ridge National Laboratory, Oak Ridge, TN
Viung C. Mei
Oak Ridge National Laboratory, Oak Ridge, TN
Fang C. Chen
Oak Ridge National Laboratory, Oak Ridge, TN
Paper No:
IMECE2003-42655, pp. 33-38; 6 pages
Published Online:
May 12, 2008
Citation
Gao, Z, Mei, VC, & Chen, FC. "CFD Solution and Experimental Testing of Buoyancy-Driven Convection Caused by Condensers Immersed in a Water Tank of HPWH." Proceedings of the ASME 2003 International Mechanical Engineering Congress and Exposition. Advanced Energy Systems. Washington, DC, USA. November 15–21, 2003. pp. 33-38. ASME. https://doi.org/10.1115/IMECE2003-42655
Download citation file:
9
Views
Related Articles
Performance of a Residential-Sized GAX Absorption Chiller
J. Energy Resour. Technol (September,2001)
Design and Performance of a Constant Temperature and Humidity Air-Conditioning System Driven by a Ground Source Heat Pump in Summer
J. Thermal Sci. Eng. Appl (March,2010)
Experimental Testing of Gerotor and Scroll Expanders Used in, and Energetic and Exergetic Modeling of, an Organic Rankine Cycle
J. Energy Resour. Technol (March,2009)
Related Chapters
Threshold Functions
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Experimental Investigation of an Improved Thermal Response Test Equipment for Ground Source Heat Pump Systems
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
ASME Section VI: Recommended Rules for the Care and Operation of Heating Boilers
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 1 Sixth Edition