X-ray CT provides imaging guidance for cryosurgery that allows 3D visualization of frozen and unfrozen tissue. Temperature in the tissue water-ice interface (0 to −10 °C) may be calibrated to Hounsfield units. However x-ray CT images and their thermal calibration can be compromised by the cryoprobes generating high-density streak artifacts. A new subtraction technique for suppression of these artifacts is proposed and tested in prostate cryosurgery simulations. By subtracting the profile without cryoprobes from the profile with cryoprobes and iceballs, we can get the combined profile of the cryoprobes and a low value background. A polynomial interpolation is performed to obtain the background profile, which is then added back to the original profile without probes. The resulting profile is then fed to a conventional filtered back-projection routine to reconstruct the probe-free image. Finally the cryoprobe pixels in the originally constructed image with probes are added back to the probe-free image to get the final artifact-suppressed image. The major advantage of this subtraction technique is that it can successfully suppress the high-density artifacts in bone abundant body regions. X-ray CT images of cryoprobe arrays in a homogeneous gelatin phantom and the pelvic region of an anthropomorphic Rando phantom containing a human skeleton were generated. After suppression, cryoprobe metal artifact streaks are reduced and visualization of the positions and dimensions of the cryoprobes are well preserved. In-vivo canine studies are planned to test this new suppression technique for cryosurgery use.
Skip Nav Destination
ASME 2002 International Mechanical Engineering Congress and Exposition
November 17–22, 2002
New Orleans, Louisiana, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
0-7918-3650-9
PROCEEDINGS PAPER
X-Ray CT High Density Artifact Suppression in Cryosurgery
Laigao Chen,
Laigao Chen
Purdue University, West Lafayette, IN
Search for other works by this author on:
Yun Liang,
Yun Liang
Indiana University Medical School, Indianapolis, IN
Search for other works by this author on:
Lisa X. Xu,
Lisa X. Xu
Purdue University, West Lafayette, IN
Search for other works by this author on:
Jikun Wei,
Jikun Wei
Purdue University, West Lafayette, IN
Search for other works by this author on:
George A. Sandison
George A. Sandison
Purdue University, West Lafayette, IN
Search for other works by this author on:
Laigao Chen
Purdue University, West Lafayette, IN
Yun Liang
Indiana University Medical School, Indianapolis, IN
Lisa X. Xu
Purdue University, West Lafayette, IN
Jikun Wei
Purdue University, West Lafayette, IN
George A. Sandison
Purdue University, West Lafayette, IN
Paper No:
IMECE2002-33698, pp. 213-218; 6 pages
Published Online:
June 3, 2008
Citation
Chen, L, Liang, Y, Xu, LX, Wei, J, & Sandison, GA. "X-Ray CT High Density Artifact Suppression in Cryosurgery." Proceedings of the ASME 2002 International Mechanical Engineering Congress and Exposition. Advances in Bioengineering. New Orleans, Louisiana, USA. November 17–22, 2002. pp. 213-218. ASME. https://doi.org/10.1115/IMECE2002-33698
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
CT Visualization of Cryoablation in Pulmonary Veins
J. Med. Devices (June,2009)
Experimental Measurements Using Digital Image Correlation Methods: Brief Background and Perspective on Future Developments
J. Eng. Mater. Technol (January,2023)
Related Chapters
Experimental Investigation of Ventilated Supercavitation Under Unsteady Conditions
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
Synthesis and Characterization of Carboxymethyl Chitosan Based Hybrid Biopolymer Scaffold
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2