A compact MEMS flowmeter was fabricated and tested for small gas flow rates from 0.5 to 10 sccm. The flowmeter was fabricated by integrating a silicon chip consisting of three surface-micromachined sensor clusters with a 60μm tall, 1.25 mm wide, and 10 mm long flow channel. Each sensor cluster in the chip consists of a pressure sensor, a surface shear stress sensor, and a temperature sensor. As gas flows through the channel, the volumetric flow rate is determined by measuring either the pressure drop in the flow direction or the local surface shear stress. The temperature sensors in the clusters mainly function as a reference for temperature compensating of the thermally based shear stress sensors. The flowmeter was calibrated in an open-loop pipe-flow facility using nitrogen as the gas medium. Based on the test results, it is clear that the pressure sensors, while capable of handling high flow rates, do not have the necessary precision level for small flow measurements. By comparison, the shear stress sensors, after proper temperature compensation, provide consistent and repeatable measurements for small flow rates. Additionally, the voltage output of the shear stress sensors also follows the 1/3 power trend, previously predicted for macro flow situations, in the small flow range tested.
Skip Nav Destination
ASME 2002 International Mechanical Engineering Congress and Exposition
November 17–22, 2002
New Orleans, Louisiana, USA
Conference Sponsors:
- Microelectromechanical Systems
ISBN:
0-7918-3642-8
PROCEEDINGS PAPER
Fabrication and Testing of a MEMS Low-Flow Meter
Jason Sheppard,
Jason Sheppard
University of Arkansas, Fayetteville, AR
Search for other works by this author on:
Jason Clendenin,
Jason Clendenin
University of Arkansas, Fayetteville, AR
Search for other works by this author on:
Steve Tung
Steve Tung
University of Arkansas, Fayetteville, AR
Search for other works by this author on:
Jason Sheppard
University of Arkansas, Fayetteville, AR
Jason Clendenin
University of Arkansas, Fayetteville, AR
Edward Chiu
Umachines, Inc.
Steve Tung
University of Arkansas, Fayetteville, AR
Paper No:
IMECE2002-33310, pp. 211-216; 6 pages
Published Online:
June 3, 2008
Citation
Sheppard, J, Clendenin, J, Chiu, E, & Tung, S. "Fabrication and Testing of a MEMS Low-Flow Meter." Proceedings of the ASME 2002 International Mechanical Engineering Congress and Exposition. Microelectromechanical Systems. New Orleans, Louisiana, USA. November 17–22, 2002. pp. 211-216. ASME. https://doi.org/10.1115/IMECE2002-33310
Download citation file:
10
Views
Related Proceedings Papers
Related Articles
Theoretical, Numerical, and Experimental Study of the Time of Flight Flowmeter
J. Fluids Eng (April,2011)
A Universal, Nonintrusive Method for Correcting the Reading of a Flow Meter in Pipe Flow Disturbed by Installation Effects
J. Fluids Eng (September,2002)
Autoclave Reliability of MEMS Pressure and Temperature Sensors Embedded in Carbon Fiber Composites
J. Electron. Packag (March,2001)
Related Chapters
Section III: Subsections NC and ND — Class 2 and 3 Components
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Fourth Edition
Cavitating Flows of Varying Temperature Liquid Nitrogen in Converging-diverging Nozzle
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential