Abstract

In this work, uniaxial tensile testing of a 63Sn-37Pb alloy with different specimen sizes and aging conditions had been carried out. Although the stress-strain responses of different specimen sizes and aging conditions differs, the ultimate strength of the specimens with 16 hours, 100°C aging are similar for the sizes tested. The specimens with 25 days, 100°C aging have different stress-strain response with different sizes, and have a lower ultimate strength and higher failure strain compared to 16 hours, 100°C aging specimens.

This content is only available via PDF.
You do not currently have access to this content.