Skip Nav Destination
Proceedings Papers
In This Volume
Volume 3: Biomedical and Biotechnology Engineering
Biomedical and Biotechnology Engineering
Biomedical Devices
Performance Assessment of a Noninvasive Swallowable Biosensor Deployment System in Microgravity
IMECE 2016; V003T04A001https://doi.org/10.1115/IMECE2016-65039
Topics:
Aircraft
,
Biosensors
,
Design
,
Endoscopes
,
Gravity (Force)
,
Linings (Textiles)
,
Monitoring systems
,
NASA
,
Reduced gravity environments
,
Reliability
Reducing Wear Debris and Increasing Lower-Limb Amputees’ Comfort by Optimizing Prosthetic Socket Design Using Local Contact Pressure Relief and Implementing Appropriate Holes
IMECE 2016; V003T04A002https://doi.org/10.1115/IMECE2016-65209
Topics:
Artificial limbs
,
Design
,
Pressure
,
Wear
,
Finite element model
,
Stiffness
,
Mechanical efficiency
,
Molecular weight
,
Optical images
,
Prostheses
A New GUI Device for Monitoring Cardiovascular Status
IMECE 2016; V003T04A004https://doi.org/10.1115/IMECE2016-65361
Thermal Drift and Dynamic Response of Micro Flow Sensors for Smart VP Shunts
IMECE 2016; V003T04A005https://doi.org/10.1115/IMECE2016-65401
Topics:
Dynamic response
,
Flow sensors
,
Sensors
,
Fluids
,
Noise (Sound)
,
Brain
,
Catheters
,
Cerebrospinal fluid
,
Deflection
,
Design
Assisted Mobility Gait Training System
Erik Shaw, Pablo Vasquez, Ryosuke Kondo, Kevin Ung, Zachary Farrer, Evan Fagerberg, Jack Baker, Bryan Yergeau, Matthew Harrison, James McCusker, Mansour Zenouzi
IMECE 2016; V003T04A007https://doi.org/10.1115/IMECE2016-65635
Topics:
Mechanical admittance
,
Health care
,
Stress
,
Feedback
,
Patient rehabilitation
,
Wheels
,
Biomedicine
,
Data acquisition
,
Gages
,
Imaging
Correlation of Strain on Instrumentation to Simulated Posterolateral Lumbar Fusion in a Sheep Model
IMECE 2016; V003T04A008https://doi.org/10.1115/IMECE2016-65696
Topics:
Instrumentation
,
Spinal fusion
,
Rods
,
Stability
,
Strain gages
,
Algorithms
,
Bone
,
Bridges (Structures)
,
Cements (Adhesives)
,
Computers
Development of a Microfabricated Sensor System to Measure Lumbar Spinal Fusion
IMECE 2016; V003T04A009https://doi.org/10.1115/IMECE2016-65703
Topics:
Sensors
,
Spinal fusion
,
Bone
,
Capacitors
,
Surgery
,
Capacitance
,
Design
,
Stiffness
,
Stress
,
Circuits
Reliability Based Design of Femoral Locking Plate Systems
IMECE 2016; V003T04A010https://doi.org/10.1115/IMECE2016-65834
Topics:
Design
,
Reliability
,
Optimization
,
Cycles
,
Design methodology
,
Failure
,
Femoral fractures
,
Finite element analysis
,
Finite element model
,
Knee
Development of the Working Fluid With Blood Viscosity for Evaluating Ablation Catheter in In Vitro System
IMECE 2016; V003T04A011https://doi.org/10.1115/IMECE2016-65975
Topics:
Ablation (Vaporization technology)
,
Catheters
,
Fluids
,
Hemorheology
,
Viscosity
,
Flow (Dynamics)
,
Myocardium
,
Biological tissues
,
Blood
,
Blood flow
Electromagnets as Actuators for a Novel 3D-Printed Musculoskeletal Prosthesis
IMECE 2016; V003T04A013https://doi.org/10.1115/IMECE2016-66396
Topics:
Actuators
,
Additive manufacturing
,
Electromagnets
,
Musculoskeletal system
,
Prostheses
,
Bone
,
Anatomy
,
Copper
,
Engineering prototypes
,
Imaging
Examining Relationships Between Device Complexity and Failure Modes of Minimally Invasive Surgical Staplers
IMECE 2016; V003T04A014https://doi.org/10.1115/IMECE2016-66750
Topics:
Failure mechanisms
,
Surgery
,
Design
,
Failure
,
Food and Drug Administration
,
Firing
,
Medical devices
,
Wounds
,
Biological tissues
,
Biomedicine
Flow Simulations to Establish the Relationship Between the Inflow Zone in the Neck of a Cerebral Aneurysm and the Positions of Struts
IMECE 2016; V003T04A015https://doi.org/10.1115/IMECE2016-67804
Topics:
Aneurysms
,
Flow simulation
,
Inflow
,
Struts (Engineering)
,
Flow (Dynamics)
,
Stents
,
Porosity
,
Errors
,
Risk
,
Blood flow
Biomedical Imaging
Clinical Applications of Bioengineering
Is the Maturation of Arteriovenous Fistulas a Mechanical or Biological Problem?
IMECE 2016; V003T04A017https://doi.org/10.1115/IMECE2016-65655
Topics:
Biomechanics
,
Blood
,
Blood flow
,
Deformation
,
Flow (Dynamics)
,
High pressure (Physics)
,
Inflow
,
Modeling
,
Shear stress
Design and Analysis of an Efficient Vaccine Cold Chain Box
Shitanshu Devrani, Sudhanshu Pandey, Shubham Chaturvedi, Krishnakumar Sankar, Shantanu Patil, K. Sridhar
IMECE 2016; V003T04A018https://doi.org/10.1115/IMECE2016-65858
Topics:
Chain
,
Design
,
Additive manufacturing
,
Appropriate technology
,
Computers
,
Engineering simulation
,
Governments
,
Insulation
,
Modeling
,
Simulation
Enhancing the Sport Performance and Quality Life of Athletes by Applying of WBV Method
IMECE 2016; V003T04A019https://doi.org/10.1115/IMECE2016-66098
Topics:
Sports
,
Vibration
,
Patient treatment
,
Accelerometers
,
Electric motors
,
Osteoporosis
,
Rotation
,
Safety
,
Sensors
,
Signals
Effects of Process Parameters on Direct Deposition Hydrogel Molding for the Fabrication Microfluidic Devices
IMECE 2016; V003T04A020https://doi.org/10.1115/IMECE2016-67301
Topics:
Hydrogels
,
Manufacturing
,
Microfluidics
,
Molding
,
Microchannels
,
Agar
,
Biomedicine
,
Construction
,
Electrospinning
,
Fibers
Computational Modeling in Biomedical Applications
The Effects of Graft Size and Insertion Site Location During Anterior Cruciate Ligament Reconstruction on Intercondylar Notch Impingement
IMECE 2016; V003T04A022https://doi.org/10.1115/IMECE2016-65152
Topics:
Anterior cruciate ligament
,
Knee
,
Engineering simulation
,
Finite element analysis
,
Geometry
,
Kinematics
,
Rotation
,
Simulation
A Computational Model of Vestibular Fluid Response to Human Body Rotation
IMECE 2016; V003T04A027https://doi.org/10.1115/IMECE2016-67035
Topics:
Fluids
,
Rotation
,
Canals
,
Displacement
,
Mathematics
,
Pendulums
,
Testing
,
Wave equations
Influence of Intracranial Pressure on the Lamina Cribrosa
IMECE 2016; V003T04A028https://doi.org/10.1115/IMECE2016-67114
Modeling and Simulation of Shoulder-Humerus Complex via Multibody Dynamics for a Walking Elder Using a Cane
IMECE 2016; V003T04A029https://doi.org/10.1115/IMECE2016-67173
Topics:
Modeling
,
Multibody dynamics
,
Simulation
,
Bone
,
Muscle
,
Tendons
,
Actuators
,
Biomedicine
,
Blades
,
Computer software
A Correlative CFD Study Between Recirculation Area and FPM in VHC Design
IMECE 2016; V003T04A030https://doi.org/10.1115/IMECE2016-67329
Topics:
Computational fluid dynamics
,
Computer software
,
Confined flow
,
Corners (Structural elements)
,
Design
,
Displacement
,
Drops
,
Drugs
,
Flow (Dynamics)
,
Geometry
Promoting Suitable Hemodynamic Conditions for Thrombus Formation in Abdominal Aortic Aneurysms With Multilayer Stents
IMECE 2016; V003T04A031https://doi.org/10.1115/IMECE2016-67460
Topics:
Aneurysms
,
Hemodynamics
,
Stents
,
Thrombosis
,
Flow (Dynamics)
,
Design
,
Porosity
,
Computational fluid dynamics
,
Geometry
,
Layer structure (Solids)
Damage Biomechanics
Buckling Analysis of Hollow Microneedle in Transdermal Drug Delivery
IMECE 2016; V003T04A034https://doi.org/10.1115/IMECE2016-65083
Topics:
Buckling
,
Drug delivery systems
,
Microneedles
,
Stress
,
Design
,
Silicon
,
Biomedicine
,
Deflection
,
Eigenvalues
,
Equilibrium (Physics)
Effects of Anatomical Site and Loading Rate on Tensile Behavior of Fiber Bundles Isolated From Nerve Roots
IMECE 2016; V003T04A035https://doi.org/10.1115/IMECE2016-66016
Topics:
Fibers
,
Elastic moduli
,
Engineering simulation
,
Failure
,
Mechanical properties
,
Simulation
,
Strength (Materials)
,
Tensile strength
,
Wounds
Macro-Micro Biomechanics Finite Element Modeling of Brain Injury Under Concussive Loadings
IMECE 2016; V003T04A036https://doi.org/10.1115/IMECE2016-66218
Topics:
Biomechanics
,
Finite element analysis
,
Modeling
,
Traumatic brain injury
,
Brain
,
Failure
,
Finite element model
,
Proteins
,
Wounds
,
Biological tissues
Behavior Evaluation of Deformation, Damage and Fracture of Biological Soft Tissue by Using Indentation Test
IMECE 2016; V003T04A037https://doi.org/10.1115/IMECE2016-66672
Topics:
Damage
,
Deformation
,
Fracture (Materials)
,
Fracture (Process)
,
Soft tissues
,
Biological tissues
,
Stress
,
Testing
,
Bullets
,
Elasticity
Non-Destructive and Failure Responses of Cervical Spine Artificial Disc Surgery for Military Applications
Narayan Yoganandan, Jason Moore, Jamie L. Baisden, Frank A. Pintar, B. Joseph McEntire, Valeta Carol Chancey
IMECE 2016; V003T04A038https://doi.org/10.1115/IMECE2016-66705
Topics:
Cervical spine
,
Defense industry
,
Disks
,
Failure
,
Surgery
,
Compression
,
Discectomies
,
Displacement
,
Biomechanics
,
Computerized tomography
Combat Helmet Design Incorporating Multiple Ballistic Threats, Brain Functional Areas and Injury Considerations
IMECE 2016; V003T04A039https://doi.org/10.1115/IMECE2016-67364
Topics:
Brain
,
Design
,
Warfare
,
Wounds
,
Deflection
,
Computer software
,
Computer-aided design
,
Explosives
,
Optimization
,
Parametric design
Novel Measurement of Intradiscal Pressure in Underbody Blast Simulation
Connor A. Bradfield, Constantine K. Demetropoulos, Connor O. Pyles, Eyal Bar-Kochba, Alexander S. Iwaskiw, Edwin B. Gienger, Andrew C. Merkle, Robert S. Armiger
IMECE 2016; V003T04A040https://doi.org/10.1115/IMECE2016-67426
Topics:
Pressure
,
Simulation
,
Testing
,
Lumbar spine
,
Biomechanics
,
Fracture (Materials)
,
Fracture (Process)
,
Intervertebral discs
,
Spinal fractures
,
Stress
Skull Deformation Has No Impact on the Variation of Brain Intracranial Pressure
IMECE 2016; V003T04A042https://doi.org/10.1115/IMECE2016-67518
Topics:
Brain
,
Deformation
,
Pressure
,
Density
,
Elasticity
,
Engineering simulation
,
Finite element analysis
,
Individual Certification Programs
,
Injury mechanisms
,
Risk
Damage Prediction for a Cervical Spine Intervertebral Disc
IMECE 2016; V003T04A043https://doi.org/10.1115/IMECE2016-67711
Topics:
Cervical spine
,
Damage
,
Intervertebral discs
,
Stress
,
Disks
,
Fatigue failure
,
Military systems
,
Soldiers
Validation of Embedded Element Method in the Prediction of White Matter Disruption in Concussions
IMECE 2016; V003T04A045https://doi.org/10.1115/IMECE2016-67785
Topics:
Anisotropy
,
Computer simulation
,
Diffusion (Physics)
,
Fibers
,
Finite element model
,
Imaging
,
Patient rehabilitation
,
Tensors
,
Wounds
Stability and Collapsing Mechanism of Cavitation-Induced Nanobubbles in Simulated Extra-Cellular Matrix (ECM) Near Neuron
IMECE 2016; V003T04A046https://doi.org/10.1115/IMECE2016-67806
Topics:
Cavitation
,
Stability
,
Brain
,
Fluids
,
Sodium
,
Traumatic brain injury
,
Blood
,
Bubbles
,
Collapse
,
Damage
A Sensitivity Study of the Porcine Head Subjected to Bump Impact
Kimberly A. Thompson, Adam C. Sokolow, Juliana Ivancik, Timothy G. Zhang, William H. Mermagen, Jr., Sikhanda S. Satapathy
IMECE 2016; V003T04A047https://doi.org/10.1115/IMECE2016-68178
Topics:
Biological tissues
,
Brain
,
Cavities
,
Engineering simulation
,
Matlab
,
Simulation
,
Skin
,
Stress
,
Three-dimensional models
,
Topology
Role of Skull Fracture on Load Transfer to Brain
IMECE 2016; V003T04A048https://doi.org/10.1115/IMECE2016-68185
Topics:
Brain
,
Skull fractures
,
Stress
,
Failure
,
Deformation
,
Fluids
,
Particulate matter
,
Pressure
Dynamics and Control of Biomechanical Systems
Finite Element Analysis of an Electro-Mechanical Knee Loading Device
IMECE 2016; V003T04A049https://doi.org/10.1115/IMECE2016-65270
Topics:
Finite element analysis
,
Knee
,
Engineering prototypes
,
Stress
,
Bone
,
Computer-aided design
,
Deformation
,
Design
,
Durability
,
Fracture (Materials)
Finite Element Analysis of an Under-Actuated Robotic Device for Knee Loading Applications
IMECE 2016; V003T04A050https://doi.org/10.1115/IMECE2016-65271
Topics:
Finite element analysis
,
Knee
,
Robotics
,
Bone
,
Cartilage
,
Design
,
Wounds
,
Biological tissues
,
Bone fractures
,
Maintenance
Powering a Lower Limb Exoskeleton Using Pneumatic Artificial Muscles
IMECE 2016; V003T04A051https://doi.org/10.1115/IMECE2016-65298
Topics:
Exoskeleton devices
,
Muscle
,
Knee
,
Maintenance
,
Stress
,
Engineering prototypes
,
Kinematics
,
Manufacturing
,
Torque
,
Weight (Mass)
Knee Internal Forces in Moderate Squat Exercise
IMECE 2016; V003T04A054https://doi.org/10.1115/IMECE2016-66626
Topics:
Knee
,
Structural mechanics
,
Anterior cruciate ligament
,
Muscle
,
Compression
,
Optimization
,
Strips
Deformation of Stenotic Blood Vessel Model Made From Poly (Vinyl Alcohol) Hydrogel by Hydrostatic Pressure
Yasutomo Shimizu, Lei Liu, Hiroyuki Kosukegawa, Kenichi Funamoto, Toshiyuki Hayase, Toshio Nakayama, Makoto Ohta
IMECE 2016; V003T04A055https://doi.org/10.1115/IMECE2016-66657
Topics:
Blood vessels
,
Deformation
,
Ethanol
,
Hydrogels
,
Hydrostatic pressure
,
Stiffness
,
Blood flow
,
Vessels
,
Diseases
,
Elasticity
Development of an Active Biomimetic-Controlled Transfemoral Knee Prosthesis
IMECE 2016; V003T04A057https://doi.org/10.1115/IMECE2016-67211
Topics:
Biomimetics
,
Knee joint prostheses
,
Cycles
,
Design
,
Knee
,
Prostheses
,
Artificial limbs
,
Echoes
,
Electromyography
,
Engineering prototypes
General
Modeling and Measurement of Temperature Distributions in Bone Drilling
IMECE 2016; V003T04A058https://doi.org/10.1115/IMECE2016-66129
Topics:
Bone
,
Drilling
,
Modeling
,
Temperature measurement
,
Biological tissues
,
Bits (Tools)
,
Temperature
,
Temperature distribution
,
Damage
,
Heat
Multiple Sclerosis Symptom Analyzer
IMECE 2016; V003T04A059https://doi.org/10.1115/IMECE2016-66217
Topics:
Biological tissues
,
Biomedicine
,
Brain
,
Design
,
Diseases
,
Drugs
,
Magnetic resonance imaging
,
Nervous system
,
Spinal cord
,
Surgery
Hierarchical Engineering Model of the Human Body
IMECE 2016; V003T04A060https://doi.org/10.1115/IMECE2016-66253
Topics:
Biological tissues
,
Biomaterials
,
Biomedicine
,
Chemical reactions
,
Design
,
Diseases
,
Drugs
,
Energy budget (Physics)
,
Energy conversion
,
Engineering models
Nonlinear Characterization of Heart Rate Variability in Normal Sinus Rhythm, Atrial Fibrillation and Congestive Heart Failure
IMECE 2016; V003T04A061https://doi.org/10.1115/IMECE2016-66836
Topics:
Heart failure
,
Cardiovascular system
,
Dynamics (Mechanics)
,
Physiology
,
Time series
,
Algorithms
,
Risk
Posters
Reduced Order Modeling and Experimental Investigation of Acoustic Particle Manipulation in Complex 3D Geometries
IMECE 2016; V003T04A063https://doi.org/10.1115/IMECE2016-66904
Topics:
Acoustics
,
Modeling
,
Particulate matter
,
Drops
,
Generators
,
Nozzles
,
Pressure
,
Equilibrium (Physics)
,
Radiation (Physics)
,
Reservoirs
CFD Analysis Comparing Steady Flow and Pulsatile Flow Through the Aorta and its Main Branches
IMECE 2016; V003T04A064https://doi.org/10.1115/IMECE2016-67155
Topics:
Aorta
,
Computational fluid dynamics
,
Flow (Dynamics)
,
Pulsatile flow
,
Atherosclerosis
,
Blood flow
,
Aortic arch
,
Pressure
,
Shear stress
Haptic and Visual Feedback Technology for Upper-Limb Disability Assessment
IMECE 2016; V003T04A065https://doi.org/10.1115/IMECE2016-67541
Topics:
Feedback
,
Haptics
,
Patient treatment
,
Robotics
,
Virtual reality
,
Algorithms
,
Artificial neural networks
,
Computers
Sport Biomechanics
The Effect of Padding Layers Arrangement on Mitigating Head Impacts
IMECE 2016; V003T04A069https://doi.org/10.1115/IMECE2016-66702
Topics:
Cushioning materials
,
Brain
,
Viscoelastic materials
,
Composite materials
,
Glass
,
Sports
,
Stiffness
,
Wounds
Tissue and Biomaterials: Modeling, Synthesis, Fabrication and Characterization
Effects of Vinyl Acetate Content and Extrusion Temperatures on Ethylene Vinyl Acetate (EVA) Tetracycline HCL Fibers Used for Periodontal Applications
IMECE 2016; V003T04A070https://doi.org/10.1115/IMECE2016-66216
Topics:
Extruding
,
Fibers
,
Temperature
,
Diseases
,
Drugs
,
Tensile strength
,
Testing
,
Cancer
,
Cavities
,
Dimensions
Measuring Compressive Modulus of Elasticity Across Cortical Bone Thickness of Mid-Diaphysis Bovine Femur
IMECE 2016; V003T04A071https://doi.org/10.1115/IMECE2016-66383
Topics:
Bone
,
Elastic moduli
,
Stiffness
,
Microhardness
,
Stress
,
ASTM International
,
Fittings
,
Vickers hardness testing
,
Young's modulus
3D Printing of Gradient Osteochondral Scaffolds Using Soy-Oil Resin
IMECE 2016; V003T04A075https://doi.org/10.1115/IMECE2016-66680
Topics:
Additive manufacturing
,
Resins
,
Biological tissues
,
Bone
,
Cartilage
,
Particulate matter
,
Physiology
,
Polymers
,
Tissue engineering
Characterization of Tissue Thermal Conductivity During a Tissue Joining Process
IMECE 2016; V003T04A076https://doi.org/10.1115/IMECE2016-66932
Topics:
Biological tissues
,
Joining
,
Thermal conductivity
,
Damage
,
Heat transfer
,
Heat
,
Heating
,
Sealing (Process)
,
Surgery
,
Temperature gradient
Shear Lag Sutures: Improved Suture Repair Through the Use of Adhesives
Stephen W. Linderman, Ioannis Kormpakis, Richard H. Gelberman, Victor Birman, Ulrike G. K. Wegst, Stavros Thomopoulos, Guy M. Genin
IMECE 2016; V003T04A077https://doi.org/10.1115/IMECE2016-67522
Topics:
Adhesives
,
Maintenance
,
Shear (Mechanics)
,
Tendons
,
Stress
,
Biological tissues
,
Design
,
Adhesion
,
Failure
,
Mechanical properties
Transport Phenomena in Biomedical Applications
Effects of Nasal Cavity and Pharyngeal Regions on Airflow Simulation and Particle Depositions in Lower Generations of the Airways
IMECE 2016; V003T04A080https://doi.org/10.1115/IMECE2016-65305
Topics:
Air flow
,
Cavities
,
Particulate matter
,
Simulation
,
Trachea
,
Flow (Dynamics)
,
Shear stress
,
Kinetic energy
,
Respiratory system
,
Turbulence
Computational Fluid Dynamics Analysis of the Bone Marrow in Cancellous Bone as a Non-Newtonian Fluid
Makoto Ohta, Wataru Sakuma, Toshio Nakayama, Hitomi Anzai, Makoto Ito, Katsuyuki Sado, Shuji Nakamura
IMECE 2016; V003T04A081https://doi.org/10.1115/IMECE2016-67006
Topics:
Bone
,
Computational fluid dynamics
,
Non-Newtonian fluids
,
Viscosity
,
Flow (Dynamics)
,
Pressure
,
Shear rate
,
Stem cells
,
Non-Newtonian flow
,
Blood
Vibration and Acoustics in Biomedical Applications
Correlating Tri-Accelerometer Swallowing Vibrations and Hyoid Bone Movement in Patients With Dysphagia
IMECE 2016; V003T04A083https://doi.org/10.1115/IMECE2016-66133
Topics:
Accelerometers
,
Bone
,
Vibration
,
Signals
,
Imaging
,
Physiology
Characterization of Lumbar-Level Spinal Fusion on the Whole Human Spine Under Vibrations
IMECE 2016; V003T04A084https://doi.org/10.1115/IMECE2016-66384
Topics:
Human spine
,
Spinal fusion
,
Vibration
,
Disks
,
Resonance
,
Finite element model
,
Intervertebral discs
,
Lumbar spine
,
Modal analysis
,
Spine mechanics
Cell Response to Cyclic Strain at Focal Adhesions
IMECE 2016; V003T04A086https://doi.org/10.1115/IMECE2016-66843
Topics:
Adhesion
,
Osteoblasts
,
Signals
,
Traction
,
Vibration
Study on Model Parameters of Focal Cooling Device Using a Peltier Element for a Living Body
IMECE 2016; V003T04A087https://doi.org/10.1115/IMECE2016-67387
Topics:
Cooling
,
Wounds
,
Heat
,
Temperature
,
Temperature control
Temporal Variation Characteristics of Analysis Accuracy in Two-Dimensional Ultrasonic-Measurement-Integrated Blood Flow Analysis
IMECE 2016; V003T04A088https://doi.org/10.1115/IMECE2016-67661
Topics:
Blood flow
,
Computational fluid dynamics
,
Errors
,
Feedback
,
Flow (Dynamics)
,
Simulation
,
Ultrasonic measurement
,
Hemodynamics
,
Noise (Sound)
Email alerts
Most Read Proceedings Papers in IMECE
IMECE2024 Front Matter
IMECE2024
The History of Heat Transfer
IMECE2001
IMECE2024 Front Matter
IMECE2024