The main goal of balloon angioplasty is to extend the active cross-section of a partly blocked artery. In the last stage of the medical operation, a metallic frame (stent) is introduced in the open space of the artery (lumen) and expanded to the desired diameter. It is generally accepted that some of the main causes of post-angioplasty restenosis are the global stresses induced in the artery by the expanding stent and the local interaction between the stent and the arterial wall. In a blocked artery a thick layer of hard plaque deposition usually covers a significant section of the wall. Therefore, to choose an appropriate stent and improve upon the angioplasty success rate, a fundamental understanding of the local interaction between the stent and the plaque, as well as between the stent and the healthy wall is vital. The goal of the present study is to find a correlation between the local thickness of the plaque layer, contact geometry and the stent/artery radial mismatch.
Skip Nav Destination
STLE/ASME 2010 International Joint Tribology Conference
October 17–20, 2010
San Francisco, California, USA
Conference Sponsors:
- Tribology Division
ISBN:
978-0-7918-4419-9
PROCEEDINGS PAPER
Post-Angioplastic Contact Mechanics With Different Levels of Artherosclerotic Plaque
M. Teodorescu,
M. Teodorescu
Cranfield University, Cranfield, UK
Search for other works by this author on:
H. Rahnejat,
H. Rahnejat
Loughborough University, Loughborough, UK
Search for other works by this author on:
Moshe Brand,
Moshe Brand
Ariel University Center of Samaria, Ariel, Israel
Search for other works by this author on:
Jacob Rosen
Jacob Rosen
University of California at Santa Cruz, Santa Cruz, CA
Search for other works by this author on:
M. Teodorescu
Cranfield University, Cranfield, UK
H. Rahnejat
Loughborough University, Loughborough, UK
Moshe Brand
Ariel University Center of Samaria, Ariel, Israel
Jacob Rosen
University of California at Santa Cruz, Santa Cruz, CA
Paper No:
IJTC2010-41145, pp. 41-43; 3 pages
Published Online:
April 14, 2011
Citation
Teodorescu, M, Rahnejat, H, Brand, M, & Rosen, J. "Post-Angioplastic Contact Mechanics With Different Levels of Artherosclerotic Plaque." Proceedings of the STLE/ASME 2010 International Joint Tribology Conference. STLE/ASME 2010 International Joint Tribology Conference. San Francisco, California, USA. October 17–20, 2010. pp. 41-43. ASME. https://doi.org/10.1115/IJTC2010-41145
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
FSI Analysis of a Human Trachea Before and After Prosthesis Implantation
J Biomech Eng (July,2011)
Shape-Memory Nitinol Tympanostomy Tube and All-in-One Introducer Device for Treatment of Otitis Media
J. Med. Devices (June,2010)
3D CAD Based Conceptual Design of a Novel Aortic Valve Stent
J. Med. Devices (June,2009)
Related Chapters
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)
Introduction to Contact Problems in Structural Mechanics
Contact in Structural Mechanics: A Weighted Residual Approach
Sthenics of Contact
Contact in Structural Mechanics: A Weighted Residual Approach