This paper presents an assessment of heat injection as a means of improving natural draft cooling tower performance. The concept involves injecting heat into the cooling tower exit air/vapor stream immediately above the drift eliminators in order to increase the difference between the density of the exit air/vapor stream and the ambient air. The density difference between the air/vapor in the cooling tower stack and the ambient air is the engine that drives airflow through the cooling tower. The enhancement of the airflow through the cooling tower (the natural draft) results in more evaporation and thus lowers the circulating water temperature. Because the heat is injected above the drift eliminators, it does not heat the circulating water. To evaluate the cooling tower performance improvement as a function of heat injection rate, a thermal/aerodynamic computer model of Entergy’s White Bluff 1 & 2 and Independence 1 & 2 (approximately 840 MW each) natural draft cooling towers was developed. The computer model demonstrated that very substantial reductions in cold water temperature (up to 7°F) are obtainable by the injection of heat. This paper also discusses a number of possible heat sources. Sources of heat covered include extraction steam, auxiliary steam, boiler blow-down, and waste heat from a combustion turbine. The latter source of heat would create a combined cycle unit with the combination taking place in the condensing part of the cycle (bottom of the cycle) instead of the steam portion of the cycle (top of the cycle).
Skip Nav Destination
2002 International Joint Power Generation Conference
June 24–26, 2002
Scottsdale, Arizona, USA
Conference Sponsors:
- Power Division
ISBN:
0-7918-3617-7
PROCEEDINGS PAPER
Improving Natural Draft Cooling Tower Performance With Heat Injection Available to Purchase
Roger Lawson
Roger Lawson
Entergy, Newark, AR
Search for other works by this author on:
Eugene Grindle
Entergy, Newark, AR
John Cooper
John Cooper & Associates
Roger Lawson
Entergy, Newark, AR
Paper No:
IJPGC2002-26028, pp. 9-14; 6 pages
Published Online:
February 24, 2009
Citation
Grindle, E, Cooper, J, & Lawson, R. "Improving Natural Draft Cooling Tower Performance With Heat Injection." Proceedings of the 2002 International Joint Power Generation Conference. 2002 International Joint Power Generation Conference. Scottsdale, Arizona, USA. June 24–26, 2002. pp. 9-14. ASME. https://doi.org/10.1115/IJPGC2002-26028
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
Dual Receiver Concept for Solar Towers up to 100 MW
J. Sol. Energy Eng (August,2006)
Cooling Tower Performance Evaluation: Merkel, Poppe, and e- NTU Methods of Analysis
J. Eng. Gas Turbines Power (January,2005)
Comparative Productivity of Distillation and Reverse Osmosis Desalination Using Energy From Solar Ponds
J. Sol. Energy Eng (November,1982)
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Lay-Up and Start-Up Practices
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration