This paper presents methods and practices of improving heat rate through testing and, most importantly, through heat rate monitoring. This work was preformed at Portland General Electric’s 585 MWe Boardman Coal Plant, which used two very different Powder River Basin and Utah coals ranging from 8,100 to over 12,500 Btu/lbm. Such fuel variability, common now among coal-fired units was successfully addressed by Boardman’s on-line monitoring techniques. Monitoring has evolved over the past ten years from a Controllable Parameters approach (offering disconnected guidance), to a systems approach in which fuel chemistry and heating value are determined on-line, their results serving as a bases for Second Law analysis. At Boardman on-line monitoring was implemented through Exergetic System’s Input/Loss Method. Boardman was one of the first half-dozen plants to fully implement Input/Loss. This paper teaches through discussion of eight in-plant examples. These examples discuss heat rate improvements involving both operational configurations and plant components: from determining changes in coal chemistry and composite heating value on-line; to recognizing the impact of individual rows of burners and pulverizer configurations; to air leakage identifications; to examples of hour-by-hour heat rate improvements; comparison to effluent flows; etc. All of these cases have applicability to any coal-fired unit.
Skip Nav Destination
2002 International Joint Power Generation Conference
June 24–26, 2002
Scottsdale, Arizona, USA
Conference Sponsors:
- Power Division
ISBN:
0-7918-3617-7
PROCEEDINGS PAPER
Performance Improvements at the Boardman Coal Plant as a Result of Testing and Input/Loss Monitoring
David A. T. Rodgers,
David A. T. Rodgers
Portland General Electric Company, Boardman, OR
Search for other works by this author on:
Fred D. Lang
Fred D. Lang
Exergetic Systems, Inc., San Rafael, CA
Search for other works by this author on:
David A. T. Rodgers
Portland General Electric Company, Boardman, OR
Fred D. Lang
Exergetic Systems, Inc., San Rafael, CA
Paper No:
IJPGC2002-26026, pp. 213-224; 12 pages
Published Online:
February 24, 2009
Citation
Rodgers, DAT, & Lang, FD. "Performance Improvements at the Boardman Coal Plant as a Result of Testing and Input/Loss Monitoring." Proceedings of the 2002 International Joint Power Generation Conference. 2002 International Joint Power Generation Conference. Scottsdale, Arizona, USA. June 24–26, 2002. pp. 213-224. ASME. https://doi.org/10.1115/IJPGC2002-26026
Download citation file:
7
Views
Related Proceedings Papers
Related Articles
Exploring a Variant of PTC 4-2013 for Real-Time Performance Monitoring of Fossil Fuel Power Plants
ASME Open J. Engineering (January,2022)
Unrestraining The Biot Number for Systems with Internal Heat Generation
J. Sol. Energy Eng (January,0001)
Topping Combustor Status for Second-Generation Pressurized Fluidized Bed Cycle Application
J. Eng. Gas Turbines Power (January,1997)
Related Chapters
ASME Section VI: Recommended Rules for the Care and Operation of Heating Boilers
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 1 Sixth Edition
General and Historical Information
Pipeline Integrity Assurance: A Practical Approach
Pipeline Integrity and Security
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards