An experimental study was carried out to investigate the dry-out critical heat flux (CHF) characteristics of R134a flow boiling in a horizontal helically-coiled tube. The test section was heated uniformly by DC high-power sources and the geometrical parameters are the outer diameter of 10 mm, inner diameter of 8.4 mm, coil diameter of 300 mm, helical pitch of 75 mm and valid heated length of 1.89 m. The experimental conditions are the outlet pressures of 0.30–0.95 MPa, mass fluxes of 60–500 kg/m2s, inlet qualities of −0.36–0.35 and heat fluxes of 7–50 kW/m2. In total of sixty-eight 0.2 mm T-type thermocouples were set along the tube to measure wall temperatures exactly. A method based on the event-driven Agilent BenchLink Data Logger Pro software was developed to determine the occurrence of CHF. It was found that the wall temperatures jumped abruptly once the CHF occurred. The CHF usually starts to form at the front and offside (270° and 90°) of the sections near outlet. The CHF value increases largely with increasing mass flux and decreases slightly with increasing pressure. It decreases nearly linearly with increasing inlet qualities, while it decreases acutely with increasing critical qualities under larger mass flux conditions. An experimental correlation was developed to estimate dry-out CHF of R134a flow boiling in horizontal helically-coiled tubes under current conditions compared with the calculated results of Bowring and Shah correlations.
Skip Nav Destination
2010 14th International Heat Transfer Conference
August 8–13, 2010
Washington, DC, USA
Conference Sponsors:
- Heat Transfer Division
ISBN:
978-0-7918-4936-1
PROCEEDINGS PAPER
Dry-Out CHF Characteristics of R134a Flow Boiling in a Horizontal Helically-Coiled Tube
Chang-Nian Chen,
Chang-Nian Chen
Shandong University, Jinan, Shandong, China
Search for other works by this author on:
Ji-Tian Han,
Ji-Tian Han
Shandong University, Jinan, Shandong, China
Search for other works by this author on:
Li Shao,
Li Shao
Shandong University, Jinan, Shandong, China
Search for other works by this author on:
Tien-Chien Jen
Tien-Chien Jen
University of Wisconsin-Milwaukee, Milwaukee, WI
Search for other works by this author on:
Chang-Nian Chen
Shandong University, Jinan, Shandong, China
Ji-Tian Han
Shandong University, Jinan, Shandong, China
Li Shao
Shandong University, Jinan, Shandong, China
Tien-Chien Jen
University of Wisconsin-Milwaukee, Milwaukee, WI
Paper No:
IHTC14-23415, pp. 759-766; 8 pages
Published Online:
March 1, 2011
Citation
Chen, C, Han, J, Shao, L, & Jen, T. "Dry-Out CHF Characteristics of R134a Flow Boiling in a Horizontal Helically-Coiled Tube." Proceedings of the 2010 14th International Heat Transfer Conference. 2010 14th International Heat Transfer Conference, Volume 1. Washington, DC, USA. August 8–13, 2010. pp. 759-766. ASME. https://doi.org/10.1115/IHTC14-23415
Download citation file:
15
Views
Related Proceedings Papers
Related Articles
Flow Boiling of R134a in Circular Microtubes—Part II: Study of Critical Heat Flux Condition
J. Heat Transfer (May,2011)
Effects of Pressure and a Microporous Coating on HFC-245fa Pool Boiling Heat Transfer
J. Heat Transfer (October,2014)
Pool Boiling Heat Transfer of Borated (H 3 BO 3 ) Water on a Nanoporous Surface
J. Heat Transfer (September,2013)
Related Chapters
Critical Heat Flux in Flow Boiling
Two-Phase Heat Transfer
Post-CHF Heat Transfer in Flow Boiling
Two-Phase Heat Transfer
Flow Boiling
Thermal Management of Microelectronic Equipment